ST7FLITE25M6TR STMicroelectronics, ST7FLITE25M6TR Datasheet - Page 144

IC MCU 8BIT 8K FLASH 20-SOIC

ST7FLITE25M6TR

Manufacturer Part Number
ST7FLITE25M6TR
Description
IC MCU 8BIT 8K FLASH 20-SOIC
Manufacturer
STMicroelectronics
Series
ST7r
Datasheets

Specifications of ST7FLITE25M6TR

Core Processor
ST7
Core Size
8-Bit
Speed
8MHz
Connectivity
SPI
Peripherals
LVD, POR, PWM, WDT
Number Of I /o
15
Program Memory Size
8KB (8K x 8)
Program Memory Type
FLASH
Ram Size
384 x 8
Voltage - Supply (vcc/vdd)
2.4 V ~ 5.5 V
Data Converters
A/D 7x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
20-SOIC (7.5mm Width)
Processor Series
ST7FLITE2x
Core
ST7
Data Bus Width
8 bit
Development Tools By Supplier
ST7FLITE-SK/RAIS, ST7MDT10-DVP3, ST7MDT10-EMU3, STX-RLINK
For Use With
497-5858 - EVAL BOARD PLAYBACK ST7FLITE
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ST7FLITE25M6TR
Manufacturer:
ST
0
Function Descriptions
– Only the ICAP2 pin can be used to perform input capture, not the ICAP1 pin. Take care that
– When OPM is used, input capture1 register is dedicated to this mode. Similarly output
– By enabling the Forced compare mode while OPM mode is enabled, the polarity of the OPM
Table 93. TIMER8_ICAP_Getvalue
Note: The input capture flag gets cleared if this function is called after the
144/235
Function Name
Function Prototype
Behaviour Description
Input Parameters
Output Parameters
Required Preconditions
Functions called
Postconditions
See also
the counter is reset each time a valid edge occurs on the ICAP1 pin and capture 1 flag can
also generate an interrupt if input capture interrupt is enabled and the instruction ‘rim’ is used
to clear the I bit.
compare2 cannot be used as level OLVL2 is dedicated to OPM.
Output waveform may change.
TIMER8_Status_Flag.
TIMER8_ICAP_Getvalue
Unsigned char TIMER8_ICAP_Getvalue(Timer8_Icap
ICAP_I)
Returns the input capture1 or input capture2 register value
depending upon the input parameter passed. This function
should be called twice in order to get both input capture1
and input capture2 register values.
TIMER8_ICAP_I
where I can be 1 or 2.
I = 1
Input capture1 register value is returned
I = 2
Input capture2 register value is returned
Input capture1 or Input capture2 register value. The re-
turned value can be in the range 0x00 to 0xFC.
ICF1 and/or ICF2 = 1
You have to call this function after the ICF1 and/or ICF2
flag is set, to get the capture value.
None
TIMER8_ICAP_Mode
Input capture1 or Input capture2 register value is returned.

Related parts for ST7FLITE25M6TR