ST7FLITE25M6TR STMicroelectronics, ST7FLITE25M6TR Datasheet - Page 47

IC MCU 8BIT 8K FLASH 20-SOIC

ST7FLITE25M6TR

Manufacturer Part Number
ST7FLITE25M6TR
Description
IC MCU 8BIT 8K FLASH 20-SOIC
Manufacturer
STMicroelectronics
Series
ST7r
Datasheets

Specifications of ST7FLITE25M6TR

Core Processor
ST7
Core Size
8-Bit
Speed
8MHz
Connectivity
SPI
Peripherals
LVD, POR, PWM, WDT
Number Of I /o
15
Program Memory Size
8KB (8K x 8)
Program Memory Type
FLASH
Ram Size
384 x 8
Voltage - Supply (vcc/vdd)
2.4 V ~ 5.5 V
Data Converters
A/D 7x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
20-SOIC (7.5mm Width)
Processor Series
ST7FLITE2x
Core
ST7
Data Bus Width
8 bit
Development Tools By Supplier
ST7FLITE-SK/RAIS, ST7MDT10-DVP3, ST7MDT10-EMU3, STX-RLINK
For Use With
497-5858 - EVAL BOARD PLAYBACK ST7FLITE
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ST7FLITE25M6TR
Manufacturer:
ST
0
Table 22. SCIx_GetBuffer
Note: This function is only for Interrupt driven mode.
Caution:
– Take care not to access the user buffer until reception is completed.
– Any data received before calling this function is ignored
– The data reception will stop as soon as an error occurs.
Function Name
Function Prototype
Behaviour Description
Input Parameter 1
Input Parameter 2
Output Parameters
Required Preconditions
Functions called
Postconditions
See also
SCIx_GetBuffer
Void SCIx_GetBuffer (unsigned char *PtrToBuffer, un-
signed char NbOfBytes)
Starts reception of the bytes and stores it into the user-
buffer in interrupt driven mode.
*PtrToBuffer
Start address of the user buffer
NbOfBytes
Total number of bytes to be received
None
1. The SCIx_Mode must have been called
2. You must enable the interrupt due to Receive Data
Ready flag.
3. You must select the Interrupt driven reception mode in
ST7lib_Config.h
4. SCIx_IT_Function must have been called inside the SCI
interrupt subroutine.
None
You must call SCIx_IsReceptionCompleted after this func-
tion to check the reception status.
SCIx_GetBuffer (Polling mode)
Function Descriptions
47/235