MCF5282CVM80 Freescale Semiconductor, MCF5282CVM80 Datasheet - Page 230

IC MPU 512K 80MHZ 256-MAPBGA

MCF5282CVM80

Manufacturer Part Number
MCF5282CVM80
Description
IC MPU 512K 80MHZ 256-MAPBGA
Manufacturer
Freescale Semiconductor
Series
MCF528xr
Datasheet

Specifications of MCF5282CVM80

Core Processor
Coldfire V2
Core Size
32-Bit
Speed
80MHz
Connectivity
CAN, EBI/EMI, Ethernet, I²C, SPI, UART/USART
Peripherals
DMA, LVD, POR, PWM, WDT
Number Of I /o
150
Program Memory Size
512KB (512K x 8)
Program Memory Type
FLASH
Ram Size
64K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 8x10b
Oscillator Type
External
Operating Temperature
-40°C ~ 85°C
Package / Case
256-MAPBGA
Controller Family/series
ColdFire
Ram Memory Size
64KB
Embedded Interface Type
CAN, I2C, SPI, UART
No. Of Pwm Channels
8
Digital Ic Case Style
MAPBGA
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MCF5282CVM80
Manufacturer:
FREESCALE
Quantity:
1 831
Part Number:
MCF5282CVM80
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Company:
Part Number:
MCF5282CVM80
Quantity:
4
Part Number:
MCF5282CVM80J
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
External Interface Module (EIM)
13.4.3
During a read cycle, the device receives data from memory or from a peripheral device.
read cycle flowchart.
The read cycle timing diagram is shown in
13-6
S5
State
Read Cycle
S5
Read
Write
1.
2.
3.
4.
5.
1.
1.
Cycle
An external device has at most two CLKOUT cycles after the start of S4 to
three-state the data bus. This applies to basic read cycles, fast termination
cycles, and the last transfer of a burst.
In the following timing diagrams, TA waveforms apply for chip selects
programmed to enable either internal or external termination. TA assertion
should look the same in either case.
Set R/W to read
Place address on A[31:0]
Assert TIP, and SIZ[1:0]
Assert TS
Negate TS
Sample TA low and latch data
Start next cycle
ColdFire processor
Low
CLKOUT
MCF5282 and MCF5216 ColdFire Microcontroller User’s Manual, Rev. 3
Table 13-3. Bus Cycle States (continued)
CS, BS, and OE are negated on the CLKOUT falling edge of S5. The processor
stops driving address lines and R/W on the rising edge of CLKOUT, terminating the
read or write cycle. At the same time, the processor negates TIP, and SIZ[1:0] on
the rising edge of CLKOUT.
Note that the rising edge of CLKOUT may be the start of S0 for the next access
cycle.
The external device stops driving data between S4 and S5.
The data bus returns to high impedance on the rising edge of CLKOUT. The rising
edge of CLKOUT may be the start of S0 for the next access.
Figure 13-5. Read Cycle Flowchart
Figure
NOTE
NOTE
13-6.
Description
1.
2.
3.
1.
2.
Decode address and select the
appropriate slave device.
Drive data on D[31:0]
Assert TA
Negate TA.
Stop driving D[31:0]
External device
Freescale Semiconductor
Figure 13-5
is a