XR21V1412IL32-F Exar Corporation, XR21V1412IL32-F Datasheet - Page 10

IC UART FIFO USB DUAL 32QFN

XR21V1412IL32-F

Manufacturer Part Number
XR21V1412IL32-F
Description
IC UART FIFO USB DUAL 32QFN
Manufacturer
Exar Corporation
Type
USB UARTsr
Datasheet

Specifications of XR21V1412IL32-F

Package / Case
32-VFQFN Exposed Pad
Features
*
Number Of Channels
2, DUART
Fifo's
128 Byte, 384 Byte
Protocol
USB 2.0
Voltage - Supply
2.97 V ~ 3.63 V
With Auto Flow Control
Yes
Mounting Type
Surface Mount
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Supply Current
16 mA
Operating Supply Voltage
2.97 V to 3.63 V
No. Of Channels
2
Data Rate
12Mbps
Uart Features
Automatic Hardware And Software Flow Control, Half-Duplex Mode, Fractional Baud Rate Generator
Supply Voltage Range
2.97V To 3.63V
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
1016-1301 - EVAL BOARD FOR XR21V1412IL
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
1016-1302

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
XR21V1412IL32-F
Manufacturer:
EXAR
Quantity:
1 800
Part Number:
XR21V1412IL32-F
Manufacturer:
EXAR/艾科嘉
Quantity:
20 000
XR21V1412
2-CH FULL-SPEED USB UART
Error flags are also available from the ERROR_STATUS register and the interrupt packet, however these flags
are historical flags indicating that an error has occurred since the previous read of the status register.
Therefore, no conclusion can be drawn as to which specific byte(s) may have contained an actual error in this
manner.
Each UART has 6 GPIOs. By default, the GPIOs are general purpose I/Os. However, there are few modes
that can be enabled to add additional feature such as Auto RTS/CTS Flow control, Auto DTR/DSR Flow
Control or Transceiver Enable Control. See
GPIO5 and GPIO4 of the UART channel can be enabled as the RTS# and CTS# signals for Auto RTS/CTS
flow control when GPIO_MODE[2:0] = ’001’ and FLOW_CONTROL[2:0] = ’001’. Automatic RTS flow control is
used to prevent data overrun errors in local RX FIFO by de-asserting the RTS signal to the remote UART.
When there is room in the RX FIFO, the RTS pin will be re-asserted. Automatic CTS flow control is used to
prevent data overrun to the remote RX FIFO. The CTS# input is monitored to suspend/restart the local
transmitter (see
1.5.3
1.5.4
GPIO
Automatic RTS/CTS Hardware Flow Control
2nd byte
2nd byte
1st byte
1st byte
Figure
4):
7 6 5 4 3 2 1 0
7 6 5 4 3 2 1 0
x x x x O F B P
x x x x O F B 8
7 or 8 bit m ode
9 bit m ode
F
IGURE
Table
3. R
ECEIVE
14.
10
D
B = B reak
F = Fram ing E rror
B = B reak
F = Fram ing E rror
O = O verrun E rror
P = P arity E rror (= ‘0’ if not enabled)
x = ‘0’
O = O verrun E rror
ATA
x = ‘0’
7 = ‘0’ in 7 bit m ode
F
ORMAT
REV. 1.1.0