Specifications of GS-BT2416C1DBAT1

Contents
Board
Processor Series
STLC2500
Wireless Frequency
2.4 GHz to 2.5 GHz
Interface Type
RS-232, USB
For Use With/related Products
GS-BT2416C1.A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
497-5793
May 2008
Introduction
This user manual details the GS-BT2416C1DB.xxx which is a Bluetooth
board including an RF antenna. The suffix xxx identifies the firmware release. There is no
suffix for HCI commands and AT1 is the suffix for AT commands.
The GS-BT2416C1DB is a board with downloaded FW which enables the user to interface
the Bluetooth
The GS-BT2416C1DBAT1 is a board with downloaded FW which enables the user to create
a Bluetooth
line which is accessible by the DB9 connector.
The GS-BT2416C1DB.xxx board can be supplied by an external 5 V DC source or via the
USB port.
Features
Figure 1.
Bluetooth
Serial interface on DB9 connector
USB connection
PCB antenna on board
Single 5 V supply voltage
CE / FCC compliant
®
®
GS-BT2416C1DB.xxx board
®
link with simple AT commands. AT commands are sent by means of the serial
V1.2 board
module with HCI commands.
GS-BT2416C1DB and GS-BT2416C1DBAT1
Bluetooth
Rev 2
®
class 1 evaluation boards using:
User manual
®
class 1 evaluation
UM0471
www.st.com
1/19

Related parts for GS-BT2416C1DBAT1

GS-BT2416C1DBAT1 Summary of contents

Page 1

... The GS-BT2416C1DB is a board with downloaded FW which enables the user to interface ® the Bluetooth module with HCI commands. The GS-BT2416C1DBAT1 is a board with downloaded FW which enables the user to create ® a Bluetooth link with simple AT commands. AT commands are sent by means of the serial line which is accessible by the DB9 connector ...

Page 2

Contents Contents 1 Recommended operating conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 2 I/O connections . . . ...

Page 3

UM0471 1 Recommended operating conditions Table 1. Recommended operating conditions Symbol VDD Board supply voltage T Operating ambient temperature stg 2 I/O connections Table 2. Board connections 1 Boot signal - If connected to GND, the module can download – ...

Page 4

I/O connections Table 2. Board connections (continued) 1 GPIO 15 2 GPIO 14 3 GPIO 13 4 GPIO 12 5 GPIO 11 6 GPIO GPIO 9 8 GPIO 8 9 GPIO 7 10 GPIO 4 11 GPIO ...

Page 5

UM0471 3 Board layout Figure 2. Board component layout 1 J5 CLASS 1 MODULE JP5 JP2 1 R3 C13 JP3 1 Board layout R4 13 Command Data ANT1 BT1 5/19 ...

Page 6

Board schematic 4 Board schematic Figure 3. Board schematic 6/19 USB_DP 32 USB_DN 31 PCM_B 30 PCM_A 29 PCM_CLK 28 PCM_SYNC 27 INT1 26 I2C1 (I2C_CLK) 25 I2C0 (I2C_DAT) GNDA 24 49 TCK (JTAG3) ANT 23 50 NTRST (JTAG0) GNDA ...

Page 7

... UM0471 5 Downloading The user has the possibility to download his own file to the GS-BT2416C1DB.xxx: ● Connect the board using an RS232 cable connected to COM1 / COM2 ● Put a jumper on JP1 (Boot pin to low level) ● Connect the power supply cable to the board ext Vin ● ...

Page 8

Certifications 6 Certifications 6.1 CE Measurements have been performed in accordance with (report available on request): ● EN 300 328 V 1.6.1 (2004-11): "Electromagnetic compatibility and radio spectrum Matters (ERM); wideband transmission systems; data transmission equipment operating in the 2.4 ...

Page 9

... Consult the dealer or an experienced radio/TV technician for help. Antenna Our board type GSBT2416C1DB is for OEM integrations only. The end-user product will be professionally installed in such a manner that only the authorized antennas are used. Caution: Any changes or modifications not expressed approved by the party responsible for compliance could cause the module to cease to comply with FCC rules part 15, and thus void the user’ ...

Page 10

Certifications It shows an example below Contains FCC ID: S9NBT2416C1DB 6.2.3 Special requirement for modular application The following requirements are fulfilled: 1. The modular transmitter must have its own RF shielding: The RF module fulfils the emission requirements of the ...

Page 11

UM0471 Table 3. RF exposure evaluation distance Channel Frequency (No.) (MHz) 00 2402,00 38 2440,00 78 2480,00 The RF module operates at low power level so it does not exceed the commission's RF exposure guidelines limits; furthermore, spread spectrum transmitters ...

Page 12

... Bluetooth replacement application. (This connection example is also given in the GS-BT2416C1.AT1 datasheet, Appendix A. 7.1 Setup and connect Two PCs and two GS-BT2416C1DBAT1 boards are needed to perform the connection Figure 6. Basic setup 12/19 ® GS-BT2416C1DBAT1 evaluation boards in a serial line /cable ...

Page 13

... Designate a GS-BT2416C1DBAT1 board to be used as "client" and suppose it has the address 0080E1000001. Hereafter this board will be referred to as "client" ● Designate a GS-BT2416C1DBAT1 board to be used as "server" and suppose it has the address 0080E1000002. Hereafter this board will be referred to as "server" ● Connect the server board using an RS232 cable ● ...

Page 14

... At this point the connection is established and GPIO1 (indicating the connection status) on both Client and Server boards becomes high. On the GS-BT2416C1DBAT1 board an LED is connected to GPIO1 and therefore the connection is also shown by an LED which is on. GPIO3 on the client board must now be put at HIGH level allowing the client to send and receive DATA from the server ...

Page 15

UM0471 ● Disconnection To disconnect, the client has to put its GPIO3 LOW (Command mode) (changing from high to low on GPIO3 appears on the client PC screen as +READY) and sends the command: AT+BTDISCONNECT OK The result is the ...

Page 16

... Each module has its own address which identifies the module itself in the network. The above examples were used with addresses 0080E1000001 and 0080E1000002. Modules on the GS-BT2416C1DBAT1 board may have different addresses. Before starting to send commands, the module address can be found with the command AT+BTSETTINGS=? which shows the relevant information of the module including the BT address ...

Page 17

UM0471 7.5 Point-to-point connections Modules with AT command firmware can only perform point-to-point connections which means that only one connection can be activated at once. A module can be connected to several other modules, but it has to disconnect from ...

Page 18

Revision history 8 Revision history Table 7. Document revision history Date 22-Oct-2007 23-May-2008 18/19 Revision 1 Initial release 2 Added: Section 6.2: FCC on page 8 UM0471 Changes ...

Page 19

... UM0471 Information in this document is provided solely in connection with ST products. STMicroelectronics NV and its subsidiaries (“ST”) reserve the right to make changes, corrections, modifications or improvements, to this document, and the products and services described herein at any time, without notice. All ST products are sold pursuant to ST’s terms and conditions of sale. ...

Related keywords