Light to Digital Converters Light to Digital 30x Sensitivity

TSL2581CS

Manufacturer Part Number
TSL2581CS
Description
Light to Digital Converters Light to Digital 30x Sensitivity
Manufacturer
TAOS
Datasheet

Specifications of TSL2581CS

Data Bus Width
16 bit
Peak Wavelength
625 nm, 850 nm
Maximum Operating Frequency
795 KHz
Operating Supply Voltage
2.7 V to 3.6 V
Operating Current
175 uA
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
- 30 C
Interface Type
I2C
Maximum Fall Time
300 ns
Maximum Rise Time
300 ns
Mounting Style
SMD/SMT
Resolution
16 bit
Package / Case
DFN-6
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TSL2581CS
Manufacturer:
TAOS
Quantity:
8 000
Control Register (00h)
NOTE: ADC_EN and POWER must be asserted before the ADC changes will operate correctly. After POWER is asserted, a 2-ms delay is
NOTE: The TSL258x device registers should be configured before ADC_EN is asserted.
The LUMENOLOGY r Company
ADC_VALID
ADC_INTR
ADC_EN
POWER
FIELD
Address
Resv
Resv
Resv
The CONTROL register primarily used to power the TSL258x device up and down as shown in Table 4.
00h
required before asserting ADC_EN.
Bit :
Resv
BIT
7:6
7
5
4
3
2
1
0
Reserved. Write as 0.
ADC Interrupt. Read only. Indicates that the device is asserting an interrupt.
ADC Valid. Read only. Indicates that the ADC channel has completed an integration cycle.
Reserved. Write as 0.
Reserved. Write as 0.
ADC Enable. This field enables the two ADC channels to begin integration. Writing a 1 activates the ADC
channels, and writing a 0 disables the ADCs.
Power On. Writing a 1 powers on the device, and writing a 0 turns it off.
Resv
6
ADC_INTR
Resv
5
r
Table 4. Control Register
ADC_VALID
www.taosinc.com
4
Resv
3
DESCRIPTION
Resv
2
LIGHT-TO-DIGITAL CONVERTER
r
ADC_EN
1
TSL2580, TSL2581
POWER
Copyright E 2010, TAOS Inc.
0
TAOS098 − MARCH 2010
Reset
00h