TSL2581CS TAOS, TSL2581CS Datasheet - Page 15

Light to Digital Converters Light to Digital 30x Sensitivity

TSL2581CS

Manufacturer Part Number
TSL2581CS
Description
Light to Digital Converters Light to Digital 30x Sensitivity
Manufacturer
TAOS
Datasheet

Specifications of TSL2581CS

Data Bus Width
16 bit
Peak Wavelength
625 nm, 850 nm
Maximum Operating Frequency
795 KHz
Operating Supply Voltage
2.7 V to 3.6 V
Operating Current
175 uA
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
- 30 C
Interface Type
I2C
Maximum Fall Time
300 ns
Maximum Rise Time
300 ns
Mounting Style
SMD/SMT
Resolution
16 bit
Package / Case
DFN-6
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TSL2581CS
Manufacturer:
TAOS
Quantity:
8 000
NOTE: Field value of 11 may be used to test interrupt connectivity in a system or to assist in debugging interrupt service routine software.
The LUMENOLOGY r Company
INTR_STOP
PERSIST
Address
FIELD
Resv
INTR
When INTR = 11, the interrupt is generated immediately following the SMBus write operation. Operation then
behaves in an SMB-Alert mode, and the software set interrupt may be cleared by an SMB-Alert cycle.
Note:
02h
Interrupts are based on the value of Channel 0 only.
Bit :
Resv
BITS
5:4
3:0
7
7
6
PERSIST FIELD VALUE
INTR FIELD VALUE
INTR_STOP
Reserved. Write as 0.
Stop ADC integration on interrupt. When high, ADC integration will stop once an interrupt is asserted. To
resume operation (1) de-assert ADC_EN using CONTROL register, (2) clear interrupt using COMMAND
register, and (3) re-assert ADC_EN using CONTROL register. Note: Use this bit to isolate a particular
condition when the sensor is continuously integrating.
INTR Control Select. This field determines mode of interrupt logic according to Table 7, below.
Interrupt persistence. Controls rate of interrupts to the host processor as shown in Table 8, below.
6
0000
0001
0010
0100
0101
1000
1001
1010
0011
0110
0111
1011
1100
1101
1110
1111
00
01
10
11
Table 8. Interrupt Persistence Select
Table 6. Interrupt Control Register
Table 7. Interrupt Control Select
5
r
INTR
Interrupt output disabled
Level Interrupt
SMBAlert compliant
Test Mode: Sets interrupt and functions as mode 10
Every ADC cycle generates interrupt
Any value outside of threshold range
2 integration time periods out of range
3 integration time periods out of range
4 integration time periods out of range
5 integration time periods out of range
6 integration time periods out of range
7 integration time periods out of range
8 integration time periods out of range
9 integration time periods out of range
10 integration time periods out of range
11 integration time periods out of range
12 integration time periods out of range
13 integration time periods out of range
14 integration time periods out of range
15 integration time periods out of range
www.taosinc.com
4
INTERRUPT PERSIST FUNCTION
READ VALUE
3
DESCRIPTION
2
LIGHT-TO-DIGITAL CONVERTER
PERSIST
r
1
TSL2580, TSL2581
Copyright E 2010, TAOS Inc.
0
TAOS098 − MARCH 2010
Reset
00h
15