MMA8452QR1 Freescale Semiconductor, MMA8452QR1 Datasheet - Page 16

Board Mount Accelerometers LOW G 3-AXIS 12BT EX VLT

MMA8452QR1

Manufacturer Part Number
MMA8452QR1
Description
Board Mount Accelerometers LOW G 3-AXIS 12BT EX VLT
Manufacturer
Freescale Semiconductor
Datasheets

Specifications of MMA8452QR1

Sensing Axis
X, Y, Z
Acceleration
2 g, 4 g, 8 g
Digital Output - Number Of Bits
8 bit, 12 bit
Supply Voltage (max)
3.6 V
Supply Voltage (min)
1.95 V
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Digital Output - Bus Interface
I2C
Shutdown
Yes
Sensitivity
256 count/g, 512 count/g, 1024 count/g
Package / Case
QFN-16
Output Type
Digital
Rohs Compliant
Yes
Peak Reflow Compatible (260 C)
Yes
Acceleration Range
± 2g, ± 4g, ± 8g
No. Of Axes
3
Ic Interface Type
I2C
Sensor Case Style
QFN
No. Of Pins
16
Supply Voltage Range
1.95V To 3.6V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MMA8452QR1
Manufacturer:
FTDI
Quantity:
1 200
Part Number:
MMA8452QR1
Manufacturer:
FREESCAL
Quantity:
5 963
Part Number:
MMA8452QR1
Manufacturer:
FREESCAL
Quantity:
1 000
Part Number:
MMA8452QR1
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
MMA8452QR1
0
Company:
Part Number:
MMA8452QR1
Quantity:
20
Part Number:
MMA8452QR1MMA8452QR1
0
5.6
and low frequencies. The high pass filter cut-off frequency can be set by the user to four different frequencies which are
dependent on the Output Data Rate (ODR). A higher cut-off frequency ensures the DC data or slower moving data will be filtered
out, allowing only the higher frequencies to pass. The embedded Transient Detection function uses the high pass filtered data
allowing the user to set the threshold and debounce counter. The Transient detection feature can be used in the same manner
as the motion detection by bypassing the high pass filter. There is an option in the configuration register to do this. This adds
more flexibility to cover various customer use cases.
due to gravity only. These functions benefit from acceleration data being filtered with a low pass filter where high frequency data is
considered noise. However, there are many functions where the accelerometer must analyze dynamic acceleration. Functions
such as tap, flick, shake and step counting are based on the analysis of the change in the acceleration. It is simpler to interpret
these functions dependent on dynamic acceleration data when the static component has been removed. The Transient Detection
function can be routed to either interrupt pin through bit 5 in CTRL_REG5 register (0x2E). Registers 0x1D – 0x20 are the
dedicated Transient Detection configuration registers. The source register contains directional data to determine the direction of
the acceleration, either positive or negative. For details on the benefits of the embedded Transient Detection function along with
specific application examples and recommended configuration settings, please refer to Freescale application note, AN4071.
5.7
setting the pulse time width and the latency time between pulses. There are programmable thresholds for all three axes. The tap
detection can be configured to run through the high pass filter and also through a low pass filter, which provides more customizing
and tunable tap detection schemes. The status register provides updates on the axes where the event was detected and the
direction of the tap. For more information on how to configure the device for tap detection please refer to Freescale application
note AN4072.
5.8
to landscape is fixed with a 45° threshold angle and a ±14° hysteresis angle. This allows the for a smooth transition from portrait
to landscape at approximately 30° and then from landscape to portrait at approximately 60°.
operates down to 29° from the flat position. All angles are accurate to ±2°.
Landscape.
16
MMA8452Q
The MMA8452Q has a built-in high pass filter. Acceleration data goes through the high pass filter, eliminating the offset (DC)
Many applications use the accelerometer’s static acceleration readings (i.e., tilt) which measure the change in acceleration
The MMA8452Q has embedded single/double and directional tap detection. This function has various customizing timers for
The MMA8452Q has an orientation detection algorithm with the ability to detect all 6 orientations. The transition from portrait
The angle at which the device no longer detects the orientation change is referred to as the “Z-Lockout angle”. The device
For further information on the orientation detection function refer to Freescale application note, AN4068.
Figure 8
and
Transient Detection
Tap Detection
Orientation Detection
Xout @ -1g
Yout @ 0g
Zout @ 0g
Figure 9
LL
Pin 1
show the definitions of the trip angles going from Landscape to Portrait and then also from Portrait to
Top View
Yout @ -1g
Xout @ 0g
Zout @ 0g
Xout @ 0g
Yout @ 1g
Zout @ 0g
PU
PD
Figure 7. Landscape/Portrait Orientation
Earth Gravity
Xout @ 1g
Yout @ 0g
Zout @ 0g
LR
Side View
Freescale Semiconductor
Zout @ -1g
Xout @ 0g
Yout @ 0g
Xout @ 0g
Yout @ 0g
Zout @ 1g
FRONT
BACK
Sensors

Related parts for MMA8452QR1