H5CX-A11-DN DC12-24/AC24 Omron, H5CX-A11-DN DC12-24/AC24 Datasheet - Page 16

Stopwatches / Timers 11-PIN RELAY OUT Multi-Fnctn

H5CX-A11-DN DC12-24/AC24

Manufacturer Part Number
H5CX-A11-DN DC12-24/AC24
Description
Stopwatches / Timers 11-PIN RELAY OUT Multi-Fnctn
Manufacturer
Omron
Datasheet

Specifications of H5CX-A11-DN DC12-24/AC24

Timing Range
0.001 s to 9999 Hrs
Supply Voltage
12 V to 24 V
Current Rating (max)
100 mA
Display Type
4 Digit LCD Backlight
Product
Digital Timer
Termination Style
Plug In
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
DC1224/AC24 H5CXA11DN H5CXA11DNDC1224/AC24
16
H5CX-A@-N/-L@-N
Timer
• Change to Function Setting Mode.
From next page
Step2
*1. If the mode is switched to the function setting mode during operation, operation will continue.
*2. Changes made to settings in function setting mode are enabled for the first time when the mode is changed to run mode.
Run mode
Also, when settings are changed, the timer is reset (time initialized and output turned OFF).
Power ON
To next page
Settings that cannot be performed with the DIP switch are performed with the operation keys.
Time range
Timer mode
Output modes
Output time
Input signal
NPN/PNP
input
Display color
Instantaneous/
time-limit
3 s min.
3 s min.
Function setting mode
* 1
* 2
The characters displayed in reverse video are the default settings.
When performing settings with operation keys only, set pin1 of the DIP switch to OFF (factory setting).
If pin 1 of the DIP switch is set to ON, the setting items indicated in
Set the time range using the
Set the timer mode using the
Set the output mode using the
Set each digit for the output time using the corresponding
Set the input signal width using the
Set the NPN/PNP mode using the
Set the display color using the
Set the function (instantaneous or time-limit operation) for the instantaneous output (output 1)
using the
Note: Only modes A-2, b, E, and Z can be selected for models with instantaneous
(If the output time is set to 0.00,
Note: Displayed for modes A, A-1, A-2, A-3, b, b-1 and S only.
Note: Not displayed for models with instantaneous contact outputs.
Note: Only displayed for the H5CX-A@ and H5CX-A11@.
Note: Displayed only for models with terminal screws (H5CX-A@).
Note: Displayed only for models with instantaneous contact outputs.
(Instantaneous) (Time-limit)
(NPN input)
(Output hold)
For details, refer to the Time Range List.
(A)
a
(20ms)
(UP)
20ms
npn
red
1c1c
hold
(Red)
up
contact outputs.
(A-1)
a-1
s
(PNP input)
For details on operations in run mode, refer to page 19.
(DOWN)
(0.01s)
0.01
grn
(Green)
down
pnp
1ms
(1ms)
2c
(A-2)
a-2
Keys.
~
99.99
(99.99s)
s
(Orange)
org
(A-3)
a-3
hold
(Red-green)
r-g
(b)
b
s
keys.
keys.
is displayed.)
keys.
keys.
b-1
(b-1)
……
(Green-red)
keys.
keys.
g-r
(d)
d
(Red-orange) (Orange-red) (Green-orange)(Orange-green)
r-o
(E)
e
h
(F)
f
will not be displayed.
o-r
keys.
(Z)
z
s
(S)
s
g-o
Time Range List
o-g
Display
0.01 s to 99.99 s
(default setting)
0.1 s to 999.9 s
1 s to 9999 s
0 min 01 s to
99 min 59 s
0.1 min to
999.9 min
1 min to
9999 min
0 h 01 min to
99 h 59 min
0.1 h to 999.9 h
1 h to 9999 h
0.001 s to
9.999 s
Set Value