SI3050-E-FT Silicon Laboratories Inc, SI3050-E-FT Datasheet - Page 90

no-image

SI3050-E-FT

Manufacturer Part Number
SI3050-E-FT
Description
IC VOICE DAA GCI/PCM/SPI 20TSSOP
Manufacturer
Silicon Laboratories Inc
Datasheet

Specifications of SI3050-E-FT

Package / Case
20-TSSOP (0.173", 4.40mm Width)
Includes
Line Voltage Monitor, Loop Current Monitor, Overload Detection, Parallel Handset Detection, Polarity Reversal Detection, TIP and
Function
Data Access Arrangement (DAA)
Interface
PCM, Serial, SPI
Number Of Circuits
1
Voltage - Supply
3 V ~ 3.6 V
Current - Supply
8.5mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Product
RF / Wireless
Supply Voltage (max)
3.6 V
Supply Voltage (min)
3 V
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
0 C
Mounting Style
SMD/SMT
Operating Supply Voltage
3.3 V
Supply Current
8.5 mA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Power (watts)
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SI3050-E-FT
Manufacturer:
Silicon Labs
Quantity:
1 794
Part Number:
SI3050-E-FTR
Manufacturer:
SILICONI/矽睿科技
Quantity:
20 000
Si3050 + Si3018/19
Register 42. GCI Control
Reset settings = 0000_0000
90
Bit
7:4
3:2
1
0
Name
Type
Bit
Reserved Read returns zero.
GCIF[1:0] GCI Data Format.
Name
B2D
B1D
D7
00 = A-Law.
01 = µ-Law.
10 = 8-bit linear. The top 8-bits of the 16-bit linear signal are transferred, and the bottom 8-bits
are discarded.
11 = 16-bit linear. B1 and B2 channels are used for the 16-bits of data. Regardless of whether
the DAA is set to transmit and receive in the B1 or B2 channel, both channels are used to
send and receive the 16-bit linear data.
Channel B2 Enable.
0 = Channel B2 transfers are disabled.
1 = Channel B2 transfers are enabled. If 16-bit linear data format is chosen, disabling the B2
channel results in only the top 8 bits of line data being sent and received in the B1 channel.
Channel B1 Enable.
0 = Channel B1 transfers are disabled.
1 = Channel B1 transfers are enabled. If 16-bit linear data format is chosen, disabling the B1
channel results in only the bottom 8 bits of line data being sent and received in the B2 chan-
nel.
D6
D5
Rev. 1.31
D4
Function
D3
GCIF[1:0]
R/W
D2
B2D
R/W
D1
B1D
R/W
D0