FC4A-K2C1 IDEC, FC4A-K2C1 Datasheet - Page 24

no-image

FC4A-K2C1

Manufacturer Part Number
FC4A-K2C1
Description
Analog Output Module
Manufacturer
IDEC
Datasheet

Specifications of FC4A-K2C1

Supply Voltage
24VDC
No. Of Analog Outputs
2
Output Voltage Dc Max
10V
External Height
90mm
Supply Voltage Min
20.4V
Operating Voltage Max
10V
Operating Voltage Min
-10V
External Width
23.25mm
External Depth
70mm
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
MicroSmart CPU Module
4: A
Programming WindLDR
4-2
Use WindLDR ver. 5.0 or later which has the ANST (Set Analog Module Parameters) macro for easy programming of ana-
log I/O modules. For a start input of the ANST macro, use special internal relay M8120 (initialize pulse) to execute the
ANST macro only once after starting the CPU.
1. Click the ANST icon
The Set Analog Module Parameters dialog box appears.
2. Select the slots where analog I/O modules are mounted.
All slots are selected to use seven analog I/O modules as default. Click the check box to deselect slots where analog I/O
modules are not mounted.
When using analog I/O modules on Slots 1, 3, 6, and 7, deselect Slots 2, 4, and 5 as shown below.
NALOG
instruction on the ladder editing screen, and click the mouse.
Or, place the cursor where you want to insert the ANST instruction on the ladder editing screen, and type ANST.
I/O C
ONTROL
from the WindLDR tool bar, then place the cursor where you want to insert the ANST
FC4A M
ICRO
S
MART
A
NALOG
I/O M
ODULE
U
SER
S
M
ANUAL

Related parts for FC4A-K2C1