4-4-10 Instruction Delete
Use
Modes
Key Sequence
Operation
Operations
CLR
DEL
3
0
The following display will appear if the Insert Key is pressed in MONITOR or
DEBUG mode. Press the Down Key to insert the instruction at the current
address.
The next address will appear after inserting an instruction. Use the Up Key to
return to the address to check the instruction that has been inserted.
To insert the TIM or CNT instruction while reading the program and the first oper-
and for the current instruction is not a bit, press the Clear Key first and then input
the name of the instruction.
Programs cannot be checked from the Programming Console. Use the GPC,
CVSS/SSS, or SYSMAC-CPT.
The message “Address too high” will appear if the user attempts to insert an
instruction at an address where no instruction currently exists and the insertion
will not be allowed.
Used to delete the instruction at a designated address in a program.
In this example, XCHG(034) at address 000301 is deleted.
1
RUN
No
Press the Delete Key. A confirmation display will appear.
Read the instruction to be deleted.
MONITOR
OK
Program read
Address set
DEBUG
OK
PROGRAM
OK
DEL
Section 4-4