CV500CN224 Omron, CV500CN224 Datasheet - Page 12

no-image

CV500CN224

Manufacturer Part Number
CV500CN224
Description
Programmable Logic Controller
Manufacturer
Omron
Datasheet

Specifications of CV500CN224

Peak Reflow Compatible (260 C)
No
Leaded Process Compatible
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Product Specifications
Absolute encoder origin setting
Electronic gear function
IN-POSITION CHECK OFF command
(G13)
Error counter reset
D code (interrupt code)
Stopover function (Code output during
axis movement)
Acceleration/deceleration time setting
for pass operations
Fixed acceleration mode for pass
operations
Servo system parameter changes
(G code: G69)
Servo-lock
Servo-unlock
Error log
Absolute value initial setting
Absolute value software reset
MPG Operating Flag
Servo data trace function
Data transfer method
Present position preset
Setting teaching address
Saving to flash memory
Emergency stop method
Automatic loading
Item
The absolute encoder origin can be
set even while servo-lock is in effect.
The numerator and denominator can
be set.
After a positioning command output
has been completed, this command
lets the next operation start without
waiting for positioning to be
completed.
The error counter can be reset for
each axis.
Can be used for notifying of the CPU
Unit of interrupts.
An M code or D code can be output
after a fixed amount of axis movement
during operation.
Either the acceleration or deceleration
time of the previous operation can be
selected for pass operations.
A fixed acceleration mode is added for
when pass operations are executed
for one axis only.
Servo system parameters can be
changed by a G code.
There is a brake signal timing
adjustment function.
There is a brake signal timing
adjustment function. Servo-unlock can
be used at any time.
Up to 20 items can be saved.
Integrated with absolute origin setting. Not supported.
Integrated with absolute origin setting.
Busy signal is used instead.
Traces servo data. Can be used with
CX-Motion.
All data is transferred using IORD or
IOWR.
Executed by IOWR.
Executed by IOWR.
Executed by IOWR.
Stopped by accumulated pulse
method or by operation command
output turning OFF after a 0 V output.
G-language programs and position
data are downloaded from a personal
computer by means of commands
from the CPU Unit, used in
combination with CX-Motion.
CS1W-MC221/MC421
Origin is set by either the
absolute-value initial setting or the
absolute-value software reset
function. (It cannot be set while
servo-lock is in effect.)
Integers only
Not supported.
Not supported.
Not supported.
Not supported.
Pass operations are executed with the
acceleration time.
Fixed acceleration time mode only
Not supported.
There is no brake signal timing
adjustment function.
There is no brake signal timing
adjustment function. Servo-unlock
cannot be used while other manual
commands are being executed.
Not supported.
Not supported.
Not supported.
Not supported.
Data is transferred by means of either
I/O transfers or IORD/IOWR.
Executed by special interrupt bit.
Executed by special interrupt bit.
Executed by special interrupt bit.
Stop by turning OFF operation
command output.
Not supported.
Motion Control Modules
C200H-MC221
11

Related parts for CV500CN224