Specifications of CV500CN224
Peak Reflow Compatible (260 C)
No
Leaded Process Compatible
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Product Specifications
CS1W-MC421
CS1W-MC421
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
Pin
+24 V
DC GND
ZALM
ZRUN
ZALMRS
---
---
ZSGND
ZSOUT
Z-GND
Z-A
Z-A
Z-B
Z-B
Z-Z
Z-Z
ZOUT
ZAGND
+F24V
FDC GND
UALM
URUN
UALMRS
---
---
USGND
USOUT
U-GND
U-A
U-A
U-B
U-B
U-Z
U-Z
UOUT
UAGND
Symbol
24 VDC input
24 VDC input
ground
Z-axis alarm input
Z-axis run output
Z-axis alarm reset
output
---
---
Z-axis SEN signal
ground
Z-axis SEN signal
output
Z-axis feedback
ground
Z-axis phase A input Phase A feedback input for the Z-axis
Z-axis phase A input Phase A feedback input for the Z-axis
Z-axis phase B input Phase B feedback input for the Z-axis
Z-axis phase B input Phase B feedback input for the Z-axis
Z-axis phase Z input
Z-axis phase Z input
Z-axis speed control
Z-axis speed control
ground
24 VDC output
24 VDC output
ground
U-axis alarm input
U-axis run output
U-axis alarm reset
output
---
---
U-axis SEN signal
ground
U-axis SEN signal
output
U-axis feedback
ground
U-axis phase A
input
U-axis phase A
input
U-axis phase B
input
U-axis phase B
input
U-axis phase Z
input
U-axis phase Z
input
U-axis speed control Speed control voltage to the U-axis driver
U-axis speed control
ground
Name
External power supply’s 24-VDC input (for
the Z-U axes)
External power supply’s 24-VDC ground
(for the Z-U axes)
Drive alarm input for the Z-axis
Drive run output for the Z-axis
Reset output for the Z-axis’s driver alarm.
Not used.
Not used.
SEN signal ground for the Z-axis
SEN signal output for the Z-axis (absolute
encoder driver)
Feedback ground for the Z-axis
Phase Z feedback input for the Z-axis
Phase Z feedback input for the Z-axis
Speed control voltage to the Z-axis driver
Ground for the Z-axis’s speed control
voltage
24-VDC input to the driver (for the Z-U
axes)
Ground for 24-VDC outputs (for the Z-U
axes)
Drive alarm input for the U-axis
Drive run output for the U-axis
Reset output for the U-axis’s driver alarm.
Not used.
Not used.
SEN signal ground for the U-axis
SEN signal output for the U-axis (absolute
encoder driver)
Feedback ground for the U-axis
Phase A feedback input for the U-axis
Phase A feedback input for the U-axis
Phase B feedback input for the U-axis
Phase B feedback input for the U-axis
Phase Z feedback input for the U-axis
Phase Z feedback input for the U-axis
Ground for the U-axis’s speed control
voltage