Process/Temperature Controller

T1610000

Manufacturer Part Number
T1610000
Description
Process/Temperature Controller
Manufacturer
Red Lion Controls
Type
Temperaturer
Datasheets

Specifications of T1610000

Operating Temperature Max
50°C
Operating Temperature Min
0°C
Output Voltage Max
250VAC
Controller Input
Thermocouple Or RTD
Supply Voltage Max
250VAC
Mounting Type
Panel Mount
Brand/series
T16 Series
Contact Form
SPST
Dimensions
49.5mmW×49.5mmH×115.3mmD
Enclosure Rating
IP65
Input Type
RTD/Thermocouple
Ip Rating
IP65
Memory
EEPROM
Output Type
Relay
Power, Rating
8 VA
Primary Type
Controller
Special Features
EEPROM
Standards
cURus, CE
Termination
Screw
Voltage, Supply
85 to 250 VAC
Thermocouple Type
J, K, T, E, R, S, B, N, C And Linear MV
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
PARAMETER VALUE CHART
DISPLAY LOOP
* Factory Setting places these parameters in the Hidden Loop (set to
HIDDEN LOOP
INPUT MODULE (
INPUT MODULE (
SP
SP
OP
ProP
Intt
dErt
AL-1
AL-2
SPSL
SPrP
trnF
tUNE
tYPE
SCAL
dCPt
FLtr
SHFt
SPLO
SPHI
InPt
F1In
tYPE
PCt
dCPt
rnd
FLtr
dSP1
InP1
dSP2
InP2
SPLO
SPHI
InPt
F1In
DISPLAY
DISPLAY
DISPLAY
DISPLAY
Lockout Module
* PROPORTIONAL BAND
* INTEGRAL TIME
* DERIVATIVE TIME
* ALARM 1 VALUE
* ALARM 2 VALUE
SETPOINT SELECT
SETPOINT RAMP RATE
CONTROL MODE TRANSFER
AUTO-TUNE START
INPUT TYPE
TEMPERATURE SCALE
DECIMAL RESOLUTION
DIGITAL FILTERING
SHIFT/OFFSET
SETPOINT LOW LIMIT
SETPOINT HIGH LIMIT
USER INPUT FUNCTION
F1 KEY FUNCTION
INPUT TYPE
PERCENT ANNUNCIATOR
DECIMAL RESOLUTION
ROUNDING INCREMENT
DIGITAL FILTERING
DISPLAY VALUE SCALING 1
INPUT VALUE SCALING 1
DISPLAY VALUE SCALING 2
INPUT VALUE SCALING 2
SETPOINT LOW LIMIT
SETPOINT HIGH LIMIT
USER INPUT FUNCTION
F1 KEY FUNCTION
SETPOINT VALUE SP1
SETPOINT VALUE SP2
OUTPUT POWER PERCENT
3-LC
PARAMETER
PARAMETER
PARAMETER
PARAMETER
1-IN
1-IN
.
) T16 ONLY
) P16 ONLY
FACTORY SETTING
FACTORY SETTING
FACTORY SETTING
FACTORY SETTING
100. 0
120
Auto
tc-
9999
PLOC
NONE
Curr
100. 0
20. 0 0
999. 9
0. 0
20
2. 0
4. 0
40
30
SP1
4. 0 0
0. 0
0. 0
NO
°F
NO
0. 0
0. 1
0. 0
0. 0
0
4
0
1
0
0
1
0
0
T16
P16
P16
P16
T16
T16
P16
T16
P16
T16
Programmer:______________________Date:_________
USER SETTING
USER SETTING
USER SETTING
USER SETTING
Controller Number:_______ Security Code:_______
HidE
in
24
OUTPUT MODULE (
LOCKOUT MODULE (
COOLING MODULE (
ALARM MODULE (
CYCt
OPAC
OPLO
OPHI
OPFL
OPdP
CHYS
tcod
AntP
ANAS
ANUt
ANLO
ANHI
SP
OP
PId
AL
CodE
SPSL
SPrP
trnF
tUNE
ALrS
ACt1
Lit1
rSt1
Stb1
AL-1
ACt2
Lit2
rSt2
Stb2
AL-2
AHYS
CYC2
GAN2
db-2
DISPLAY
DISPLAY
DISPLAY
DISPLAY
CYCLE TIME
CONTROL ACTION
OUTPUT POWER LOWER LIMIT
OUTPUT POWER UPPER LIMIT
SENSOR FAIL POWER PRESET
OUTPUT POWER DAMPENING
ON/OFF CONTROL HYSTERESIS
AUTO-TUNE CODE
ANALOG OUTPUT RANGE
ANALOG OUTPUT ASSIGNMENT
ANALOG UPDATE TIME
ANALOG LOW SCALING
ANALOG HIGH SCALING
CYCLE TIME
RELATIVE GAIN
DEADBAND
SETPOINT ACCESS
OUTPUT POWER ACCESS
PID VALUE ACCESS
ALARM VALUE ACCESS
ACCESS CODE
SETPOINT SELECT ACCESS
SETPOINT RAMP ACCESS
TRANSFER CONTROL ACCESS
AUTO-TUNE ACCESS
RESET ALARMS ACCESS
ALARM 1 ACTION
ALARM 1 ANNUNCIATOR
ALARM 1 RESET MODE
ALARM 1 STANDBY
ALARM 1 VALUE
ALARM 2 ACTION
ALARM 2 ANNUNCIATOR
ALARM 2 RESET MODE
ALARM 2 STANDBY
ALARM 2 VALUE
ALARM 1 & 2 HYSTERESIS
PARAMETER
PARAMETER
PARAMETER
PARAMETER
4-AL
2-OP
5-O2
3-LC
)
)
)
)
FACTORY
FACTORY
FACTORY
FACTORY
SETTING
SETTING
SETTING
SETTING
0. 2
4-20
100. 0
dISP
dISP
HIdE
HIdE
HIdE
HIdE
AuHI
Auto
AuHI
Auto
0. 1
rEv
100
LOC
LOC
LOC
nor
nor
2. 0
3
1
2
OP
0. 0
2. 0
1. 0
NO
1
0
0
0
0
0
0
0
T16
T16
P16
P16
T16
P16
USER SETTING
USER SETTING
USER SETTING
USER SETTING

Related parts for T1610000