ZVT-E-IF 10K3A1 UA (UNITED AUTOMATION), ZVT-E-IF 10K3A1 Datasheet

SENSOR, TEMPERATURE, ZVT-E-IF

ZVT-E-IF 10K3A1

Manufacturer Part Number
ZVT-E-IF 10K3A1
Description
SENSOR, TEMPERATURE, ZVT-E-IF
Manufacturer
UA (UNITED AUTOMATION)
Datasheet

Specifications of ZVT-E-IF 10K3A1

Thermocouple Type
NTC
Operating Temperature Max
65°C
Operating Temperature Min
0°C
External Length / Height
50mm
Response Time
14s
External Diameter
6.4mm
Lead Length
1m
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
1.
2.
3.
4.
5.
6.
7.
8.
9.
10. Switch and turn dial to required temperature and allow system to heat up to a steady
11. If output remains off, check for open or short circuit in sensor circuit, and if output
12.
CE MARKING
This product carries a “CE” marking. For further information, the see the
RECOMMENDATION section or contact our sales desk.
MAXIMUM OUTPUT RMS CURRENT (A)
Max unit temperature
Without extra heatsink
+Heatsink 100 x 100 x 3mm
+Heatsink 170 x 170 x 3mm
OPERATION
Peel adhesive back off dial and fit over 10mm panel hole.
See the table below for heatsink requirements & expected ambient temperature, to
calculate the maximum current rating.
Check that the voltage rating & sensor type is correct.
For ZVT-16-IF only: Apply a ‘thin smear’ of heatsink paste for good thermal coupling
and Insert unit through 10mm panel hole. Affix dial and extra heatsink as appropriate,
ensuring equipotential bonding (Earth bonding) and tighten front nut..
Before fitting control knob, turn temperature control fully anti-clockwise to the
mechanical stop.
Fit and align control knob to coincide with the dial mark below 0ºC
Make wire connections to rear terminals. To monitor supply and load conditions fit
neons across the relevant terminals.
Note that unit will not operate or indicate correctly and Triac will not latch on with
loads of less than 200W.
Set Prop. Band (internally [25-IF] or via rear panel [16-IF]) fully anti-clockwise.
state. If temperature is unstable turn Prop. Band clockwise in small steps over
several minutes until stable conditions are obtained, characterised by a steady output
On/Off ratio.
stays on, check position of sensor relative to heated zone. The correct sensor
temperature set points for resistance are:-
Do not use Megger or other high voltage equipment as the voltage rating may be
exceeded and damage the internal components.
100ºC @
25ºC @
0ºC @
CONTROLLER & 10K3A1-SENSOR
INSTALLATION INSTRUCTIONS
32.6K
10K
680
INSTALLATION
ZVT-16/25-IF
20ºC
10
14
16
50ºC
12
16
7
65ºC
10
15
5
RoHS Compliant
2002/95/EC
Directive
INSTALLATION
ZVT-16/25-IF
X10612
RECOMMENDATION
The ZVT-E-IF-10K3A1 is an NTC type thermistor, sealed in a stainless steel probe with 1mtr.
of white PTFE sensor connections and earth leads.
It is designed for use with ZVT-16-IF and ZVT-25-IF flicker inhibited power temperature
controllers. See Data sheets X10511 and X10542 respectively.
NOTE:
performance reaction time, i.e. for thermal bonding of sensor to metal heatsink, it is
recommended that heatsink paste is used.
Other documents, which may be appropriate for your applications, are available on request,
CODE
X10229
X10213
X10255
X10511
X10542
AP02/4
NOTE. It is recommended that installation and maintenance of this equipment should be
carried out with reference to the current edition of the I.E.E. Wiring Regulations BS7671, by
suitably qualified/trained personnel. The regulations contain important requirements regarding
the safety of electrical equipment. For International Standards refer to I.E.C. Directive I.E.C.
950.
ORDER CODE:
Good thermal bonding of sensor is required, where appropriate, to ensure controller
IDENTITY
RFI
ITA
SRA
ZVT1/2-16
ZVT1/2-25
COS
State part number: ZVT-E-IF-10K3A1
1Southport Business Park
Kew
Southport, PR8 4HQ
ENGLAND
Page No. 2 of 2
DIMENSIONS AND SPECIFICATIONS
UNITED AUTOMATION LIMITED
DESCRIPTION
Filter recommendation - addressing EMC directive.
Interaction, uses for phase angle and for burst fire control.
Safety requirements - addressing the Low Voltage Directive
(LVD) including :-Thermal data/cooling ; “Live” parts warning
& Earth requirements; Fusing recommendations.
16A Zero voltage Temperature controller
25A Zero voltage Temperature controller
UAL Conditions of sale
Issue 2
APPLICATIONS
Tel: 0044 (0) 1704 – 516500 Main
Tel: 0044 (0) 1704 – 516516 Sales
Fax: 0044 (0) 1704 – 516501
Enquiry@united-automation.com
THIS UNIT MUST BE EARTHED
Date
Enclosed, inhibited flicker sensor.
12/03