01230.9-01 STEGO, 01230.9-01 Datasheet - Page 3

Humidity And Temperature Control

01230.9-01

Manufacturer Part Number
01230.9-01
Description
Humidity And Temperature Control
Manufacturer
STEGO
Datasheet

Specifications of 01230.9-01

Mounting Type
DIN Rail
Operating Voltage Max
120V
Operating Temperature Max
60°C
Output Type
Temperature
Supply Voltage
120VAC
Temperature Accuracy ±
1K
Humidity Range
50 To 90% RH
Operating Temperature Min
0°C
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Installation notes:
1. The airflow monitor must not be installed in the impact range of permanent magnets or ferrous metals in order to avoid possible interference problems.
2. A suitable distance from electromagnetic fields, e.g. generated by transformers, motors, etc., must be maintained in order to avoid possible interference problems. Interferences must
be checked with an oscillograph and the mounting position of the airflow monitor should be adjusted if necessary.
3. Avoid installing the airflow monitors in areas where air pockets or turbulence can be expected.
4. Ambient air with a high dust content should be avoided.
As there are many different conditions of use, suitability of this product must be assessed by the end user in its final application.
Application:
The LC 013 is used as a signal contact to monitor fans or filter fans.
It can be connected to monitoring systems or can directly switch
alarm devices, such as LED's or signal lamps. Loads with capaci-
ties exceeding the indicated switching capacity must be switched
via a relay, e.g. electronic relay SM 010. The airflow monitor with
NC contact closes upon loss of air movement, indicating fan fail-
ure (e.g. red signal lamp). The NO contact closes when fan is in
operation and indicates fan is operating correctly.
LC 013 Airflow Monitor with mounting clamp and mounting clip
Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application.
LCF 013 Airflow Monitor integrated in plastic fingerguard
80 x 88
STEGO, Inc. · 1395 South Marietta Parkway · Building 800 · Marietta, GA 30067 · Tel: (770) 984-0858 · Fax: (770) 984-0615
Description
92 x 92 / 120 x 120
Toll free: 1-888-783-4611 (US & Canada only) · www.stegousa.com
Wiring example
| |
The airflow monitor is designed to indicate either the loss of air movement (NC) of any fan or
that air flow is present (NO). The contact detects air movement regardless of direction of air.
Its simple mechanical operation makes it a viable alternative to electronic monitoring systems.
Note: The product of switching voltage and switching current must not exceed 10W. The max. voltage and max. current
must not be exceeded, not even short-term (voltage/current peaks). The resulting voltage and current peaks of inductive or
capacitive loads must be restricted by a contact protection circuit.
Magnetic reed switch contact
Wide range of application
Small size
Easy to install
Technical Data
Contact type
Max. switching voltage
Max. switching current
Max. switching capacity
Switching threshold of airflow velocity
Max. airflow velocity
Contact resistance
Max. air humidity
Service life
Connection
Housing
Mounting
Mounting position
Operating temperature
Storage temperature
Protection type
Approvals
Normally Closed (NC)
Normally Open (NO)
Part No. (NC)
+ _
01300.0-00
01301.0-00
01302.0-00
01303.0-00
LC 013 / LCF 013 Airflow Monitor
Part No. (NO)
e.g. Signal Device
01300.1-00
01301.1-00
01302.1-00
01303.1-00
reed / magnet contact
switch contact open when air is flowing
switch contact closed when air is flowing
NC: 240VDC (UL), 240V AC/DC (VDE) / NO: 60VDC
NC: DC 500mA / NO: DC 170mA
10W (resistive load)
> 8.2 ft/sec (2.5m/s) - hysteresis: approx. 3.3 ft/sec (1m/s)
165 ft/sec (50m/s)
< 370m
70% RH (not condensing)
> 100,000 cycles
2 x single strand AWG 26, length 19.7” (500mm), tip of
strandedwire stripped 5mm and tinned (NC: black, NO: blue)
plastic, UL 94HB, black
mounting clamp or mounting clip,
aslo available integrated in fingerguard (LCF 013) - see table
bidirectional tab perpendicular to airflow
-4 to +122°F (-20 to +50°C)
-4 to +176°F (-20 to +80°C)
IP20
UL File No. E250507, VDE
3.15 x 3.46 x 0.4” (80 x 88 x 10.5mm)
1.3 x 0.7 x 0.3” (34 x 17.5 x 7.5mm)
4.7 x 4.7 x 0.4” (120 x 120 x 10mm)
˜
3.6 x 3.6 x 0.4” (92 x 92 x 10mm)
(with wire)
Mounting clamp
Mounting clip
Dimensions
0.2” (4.2 mm)
0.7 oz. (20g)
0.7 oz. (20g)
1.1 oz. (30g)
0.2 oz. (5g)
(approx.)
Weight

Related parts for 01230.9-01