MCR-C-1-1-00-DC Phoenix Contact, MCR-C-1-1-00-DC Datasheet

no-image

MCR-C-1-1-00-DC

Manufacturer Part Number
MCR-C-1-1-00-DC
Description
INTERFACE ANALOG
Manufacturer
Phoenix Contact
Datasheet

Specifications of MCR-C-1-1-00-DC

Input Type
0/4 - 20mA
Output Type
0/4 - 20mA
No. Of Output Channels
1
Accuracy
± 0.2%
Approval Bodies
UL Recognised
External Depth
114.5mm
External Length / Height
99mm
External Width
12.5mm
Input Voltage
RoHS Compliant
Input Voltage Max
30VDC
Rohs Compliant
Yes
MCR-C-...-DC
MCR 3-Way Isolation Amplifier
INTERFACE
Data Sheet
Description
MCR 3-way isolation amplifiers are used to electrically
isolate and convert analog signals.
The blocks provide electrical isolation of analog standard
signals. The module input and output are supplied via
integrated DC/DC converters, which are electrically isolated
from the mains (3-way isolation, see Figure 1).
The MCR modules ensure the safe decoupling of a sensor
circuit from the evaluation circuit and also prevent the
negative effects of several sensor circuits connected with
one another. 3-way isolation enables the universal use of
modules both locally and close to the control system for
signal conversion and electrical isolation as well as on the
transmission path for jumpering high load resistors.
100237_02_en
Make sure you always use the latest documentation.
It can be downloaded at www.download.phoenixcontact.com.
A conversion table is available on the Internet at
http://www.download.phoenixcontact.com/general/7000_en_00.pdf.
This data sheet is valid for all products listed on the following page:
Phone: +49 - 52 35 - 30 0 • Fax: +49 - 52 35 - 34 12 00 • www.phoenixcontact.com
PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany
www.phoenixcontact.com/salesnetwork
© PHOENIX CONTACT - 12/2005
Method of Operation
The analog signal is first modulated and then electrically
isolated using a transformer.
The electrically isolated signal is then provided at the
output, demodulated, filtered, and amplified.
The space-saving 12.5 mm wide ME housing, with plug-in
connection technology, enables the 20 V DC ... 30 V DC
supply to be quickly looped through using pre-assembled
wire jumpers.
MCR 3-way isolation amplifiers can be snapped onto
symmetrical DIN rails according to EN 60715.
Figure 1
3-way isolation
U,
I
V c
V c
U,
I
1

Related parts for MCR-C-1-1-00-DC

MCR-C-1-1-00-DC Summary of contents

Page 1

... The module input and output are supplied via integrated DC/DC converters, which are electrically isolated from the mains (3-way isolation, see Figure 1). The MCR modules ensure the safe decoupling of a sensor circuit from the evaluation circuit and also prevent the negative effects of several sensor circuits connected with one another ...

Page 2

... V ... 10 V MCR 3-way isolation amplifier, for electrical isolation of analog signals, input signal ... 10 V, output signal ... 20 mA MCR 3-way isolation amplifier, for electrical isolation of analog signals, input signal ... 20 mA, output signal ... 20 mA MCR 3-way isolation amplifier, for electrical isolation of analog signals, input signal ...

Page 3

... MCR-C-I-U-0-DC MCR-C-U-U-DC MCR-C-I-U-4-DC MCR-C-U-I-4-DC MCR-C-I-I-04-DC MCR-C-I-I-40-DC General Data Supply voltage Operating current (without load current) Transmission error MCR-C-U-I-0-DC MCR-C-I-I-00-DC MCR-C-I-U-0-DC MCR-C-U-U-DC MCR-C-I-U-4-DC MCR-C-U-I-4-DC MCR-C-I-I-04-DC MCR-C-I-I-40-DC Temperature coefficient Limit frequency (3 dB) Test voltage Input/output Input/supply Output/supply Ambient operating temperature range Approvals Connection type ...

Page 4

... Class A: Industrial application, without special installation measures. Dimensions 99 Figure 2 Dimensions (in mm) 100237_02_en 1 EN 61000-4-2 Criterion air discharge EN 61000-4-3 Criterion A 10 V/m 10 V/m EN 61000-4-4 Criterion B I/O/S EN 61000-4-5 Criterion 0.5 kV/2 Ω 61000-4-6 Criterion A I/O 55011 Class A 12,5 MCR-C-...- kV/5 kHz PHOENIX CONTACT 4 ...

Page 5

... Metal lock for fastening on the DIN rail Transmission Characteristic Curve OUT [%] 100 -100 U -110% -100 Figure 4 Transmission characteristic curve 100237_02_en Block Diagram I/U GND Figure © PHOENIX CONTACT 12/2005 + 110% 105% 100 IN [%] IN OUT Block diagram PHOENIX CONTACT MCR-C-...- I/U 6 GND 2 7 20...30V 8 GND 3 5 ...