PGr-7200 SerIeS
Feeder Protection Relay
NOTE: The PGR-7200 consists of the Feeder Protection Relay (pictured above)
and the PGA-0CIM Current Input Module (not pictured).
POWR-GARD
PHASE CURRENT
TRANSFORMERS
PGC 2000 SERIES
13
12
See pg. 31-36 for Current Transformer Selection Guide and
Accessory Information.
Included (See Ordering Info)
POWR-GARD
CURRENT INPUT MODULE
RELAY 2
11
14
POWR-GARD
FEEDER PROTECTION RELAY
PGR-7200 SERIES
PGA-0CIM
CIM
10
15
®
31
®
16
9
POWR-GARD
CURRENT
TRANSFORMER
PGC FAMILY
30
I/0 MODULE
TEMPERATURE INPUT
8
17
29
®
7
18
28
RELAY 1
®
6
19
RELAY 3
27
5
26
DIG IN
21
4
25
CONTROL
22
POWER
3
POWR-GARD
POWR-GARD
Feeder Protection (PGr 7000 Family)
23
4-20 mA
+
ANALOG
OUTPUT
2
24
1
20
Description
The PGR-7200 Feeder Protection Relay provides integrated
protection, metering, and data-logging functions. The relay can be
programmed using the front-panel operator interface, the TIA-232
port, or an optional communications network.
Applications
The PGR-7200 is used to protect distribution feeders in
processing, manufacturing, petroleum, chemical, mining,
forestry, and water and waste treatment facilities.
Features/Benefits
Specifications
IEEE Device Numbers
Input Voltage
Power-up Time
ride-Through Time
24-Vdc Source
AC Measurements
Frequency
relay Contacts
Approvals
Communications
Analog Output
Conformally Coated
Warranty
Mounting
NOTE: The PGR-7200 consists of the Feeder Protection Relay and the PGA-0CIM Current Input
Module (not pictured). To order the relay only, add (-FPU) to the part number listed above.
Ordering Information
®
®
PGR-7200-00-00
PGR-7200-01-00
PGR-7200-02-00
PGR-7200-04-00
Eight functions to protect against overcurrent, ground faults,
and phase loss
IEC and IEEE overcurrent protection curves to coordinate
with upstream and downstream devices
CT saturation compensation
Thermal element active below overcurrent pickup
Definite- and inverse-time ground-fault protection
Two set-point groups can be used for:
Standard TIA-232 interface with Modbus
Optional TIA-485 with Modbus
Protection Relays, Monitors & Systems
Protection Relays, Monitors & Systems
Maintenance setting to reduce Arc-Flash Hazards
Two different loads
RS-232 Communications
RS-232 & RS-485 Communications
RS-232 & DeviceNet™ Communications
RS-232 & Ethernet Communications
26, 46, 49, 50, 50G, 50N, 51, 51G, 51N, 74, 86
65–265 Vac, 30 VA; 80–275 Vdc, 25 W
800 ms at 120 Vac
100 ms minimum
400 mA maximum
True RMS and DFT, Peak 32 samples/cycle and
positive and negative sequence of fundamental
50 or 60 Hz
N.O. and N.C.
CSA certified to US and Canadian standards
RS-232, RS-485, DeviceNet™, Ethernet
4–20 mA, programmable
Standard
Limited lifetime
Panel, Surface (optional)
®
RTU and Allen-Bradley
®
RTU
®