PGA-016A Littelfuse Inc, PGA-016A Datasheet - Page 23

no-image

PGA-016A

Manufacturer Part Number
PGA-016A
Description
BULK / WATERTIGHT COVER FOR PGR-6200 / PGR-7200
Manufacturer
Littelfuse Inc
Datasheet

Specifications of PGA-016A

Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
© 2009 Littelfuse
GROUND-CHECK
TERMINATION
PGA-0TA6 or
POWR-GARD
Supplemental Monitoring (PGM 8000 Family)
PGM-8134 SerIeS
Ground Continuity Monitor
GROUND
PGA-0TA7
GROUND
CONTROL
CHECK
CABLE
CABLE
POWER
See pg. 31-36 for Current Transformer Selection Guide and
Accessory Information.
POWR-GARD
1
2
3
4
7
8
5
6
POWR-GARD
GROUND CONTINUITY MONITOR
PGR-8134 SERIES
®
®
Protection Relay Catalog
Protection Relays, Monitors & Systems
®
GROUND
GROUND
VERIFICATION
TRIP A
TRIP B
CHECK
FAULT
FAILSAFE
GC TEST
CT
RESET
LATCH
GC
10
12
13
15
16
18
11
14
17
19
20
21
22
23
24
25
26
27
28
9
POWR-GARD
GROUND FAULT
CURRENT
TRANSFORMER
PGC 4000
FAMILY
®
21
Description
The PGM-8134 is a microprocessor-based, combination
ground-wire monitor and ground-fault relay for resistance-
grounded or solidly grounded systems. It continuously
monitors the integrity of the ground wire to protect portable
equipment from hazardous voltages caused by ground faults.
Applications
The PGM-8134 is field proven in monitoring trailing cables on
large mobile equipment such as cranes, pumps, and shore-
to-ship power. The PGM-8134 is used to monitor the ground
wire and detect ground faults in portable power cables that
incorporate a ground-check conductor (pilot wire). Applications
include shore-to-ship power cables, dockside cranes, stacker-
reclaimers, submersible pumps, and portable conveyors.
Features/Benefits
Specifications
IEEE Device Numbers
Input Voltage
Dimensions
Trip level Settings
Trip Time Settings
Contact Operating Mode
Harmonic Filtering
Test Button
reset Button
CT loop Monitoring
relay Contacts
Approvals
Conformally Coated
Warranty
Mounting
Ordering Information
PGM-8134-00
Zener-characteristic termination assembly provides
reliable ground-check loop verification
Loop-resistance calibration not required
High-induced-ac rejection makes unit suitable for
applications with high voltages and long cables
LED indication of ground-check and ground-fault circuit
status, control power, current-sensor verification, and
system health
DFT (harmonic) filter prevents false operation
Conformally coated circuit boards for circuit protection in
corrosive atmospheres
Fail-safe ground-check circuit
60-265 Vac; 80-370 Vdc Control Power
www.littelfuse.com/series/PGR-8134.html
Selectable fail-safe or non-fail-safe
3GC, 50G, 50N, 51G, 51N,
60–265 Vac; 80–370 Vdc 15W
H 213 mm (8.4”); W 99 mm( 3.9”);
D 145 mm (5.7”);
0.5 –12.5 A
0.1–2.5 s
Standard
Standard
Standard
Standard
Isolated N.O. and N.C. Contacts
CSA certified to US and Canadian standards
Standard
5 Year
Panel, Surface (optional)

Related parts for PGA-016A