E1ZTP 230V AC TELE, E1ZTP 230V AC Datasheet

no-image

E1ZTP 230V AC

Manufacturer Part Number
E1ZTP 230V AC
Description
STAIRCASE-TIMER
Manufacturer
TELE
Datasheet

Specifications of E1ZTP 230V AC

Impulse Relay (4 Ft.)
Contact Type
Time Range
0.5 To 12min
Svhc
No SVHC (18-Jun-2010)
Contact Current Max
16A
External Depth
60mm
External Length / Height
87mm
Mounting Type
DIN Rail
Output Type
Relay
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
ENYA series
Switch-off warning
Retrigger, time extension function programmable
Energy saving function
Impulse switch mode selectable
Low switching noise
High switching capacity, 80A peak inrush current
Automatic 3/4 - wire detection
Push-button glow lamp load up to 100mA
Width 17.5 mm
Installation design
Technical data
1. Functions
Electronic staircase lighting timer with switch-off warning.
The control input allows the connection of pushbuttons with a total
glow lamp load up to 100mA and enables the application in 3- or 4-wire
circuits. The unit can be retriggered via the connected pushbuttons.
A long keypress will switch off the light (energy saving function).
A fast sequence of pushes (pumping) will extend the period to a multiple
of the selected value. Depending upon distinct type, the following
operating methods can be selected by the controls on the unit:
Function sets on distinct types are according to table ordering
information or printing on the unit.
2. Time range
Adjustment range
Time
3. Indicators
Green LED U ON:
Yellow LED ON/OFF:
4. Mechanical design
Self-extinguishing plastic housing, IP rating IP 40
Mounted on DIN-rail TS 35 according to EN 60715
Mounting position: any
Shockproof terminal connection according to VBG 4 (PZ1 required),
IP rating IP20
Tightening torque: max. 1Nm
Terminal capacity:
5. Input circuit
Supply voltage:
Nominal voltage:
Tolerance:
Rated consumption:
Rated frequency:
Duty cycle:
Reset time:
Hold-up time:
Residual ripple for DC:
Drop out voltage:
Overvoltage category:
Rated surge voltage:
TW Automatic timer with switch-off warning
T
1
0
P
PN Impulse switch mode power fail latch (only types with option PN)
1 x 0.5 to 2.5mm² with/without multicore cable end
1 x 4mm² without multicore cable end
2 x 0.5 to 1.5mm² with/without multicore cable end
2 x 2.5mm² flexible without multicore cable end
Automatic timer without switch-off warning
Steady light (ON)
Switch-off
Impulse switch mode without time function (only types with option P)
0,5 - 12min (in function T, TW)
Staircase lighting timer electronic
indication of supply voltage
indication of relay output
terminals L - N
see table ordering information or
printing on the unit
-15% to +10%
2VA (1,0W)
AC 48 to 63Hz
100%
500ms
-
-
>30%
III (in accordance with IEC 60664-1)
4kV
www.tele-online.com
6. Output
1 normally open contact terminals L - 18
Rated voltage:
Switching capacity:
If the distance between the devices is less than 5mm!
Switching capacity:
If the distance between the devices is greater than 5mm!
Start-up peak (20ms):
Mechanical life:
Electrical life
Resistive load:
Lamp load:
7. Control input B1
Connection not potential free: pushbutton B1-N (3-conductor circuit)
Glow lamp load:
Overload prodection:
8. Additional control input (only types with option C)
Connection:
Voltage range:
Galvanic isolation:
Overvoltage category:
Rated surge voltage:
9. Accuracy
Base accuracy:
Adjustment accuracy:
Repedition accuracy:
Voltage influence:
Temperature influence:
10. Ambient conditions
Ambient temperature:
Storage temperature:
Transport temperature:
Relative humidity:
Pollution degree:
11. Weight
Single packing:
250V AC
10A continuous current
16A continuous current
80A
30 x 10
10
80.000 operations at 1000W 250V
pushbutton B1-L (4-conductor circuit)
max. 100mA parallel to the pushbuttons
yes, electronic
control voltage on terminals C1(+)-C2
8 ... 230V AC/DC
yes, basic isolation
III (in accordance with IEC 60664-1)
4kV
±5% of maximum scale value
<15% of maximum scale value
<2%
-
≤1%
-25 to +55°C
-25 to +70°C
-25 to +70°C
15% to 85%
(in accordance with IEC 60721-3-3
class 3K3)
2, if built-in 3
(in accordance with IEC 60664-1)
106g
5
operations at 16A 250V
6
operations
E1ZT

Related parts for E1ZTP 230V AC

E1ZTP 230V AC Summary of contents

Page 1

... Adjustment accuracy: Repedition accuracy: Voltage influence: Temperature influence: 10. Ambient conditions Ambient temperature: Storage temperature: Transport temperature: Relative humidity: Pollution degree: 11. Weight Single packing: www.tele-online.com E1ZT 250V AC 10A continuous current 16A continuous current 80A operations 6 10 operations at 16A 250V 5 80.000 operations at 1000W 250V pushbutton B1-L (4-conductor circuit) max ...

Page 2

... R. (central OFF) Mode <2s >2s <2s C1-C2 R Mode <2s >2s <2s C1-C2 R Ordering Informations Types Functiones E1ZTP 230V AC TW E1ZTPNC 230V RELEASE 2009/07 Subject to alterations and errors Connections 3-wire-circuit <2s 3t 4-wire-circuit with attic illumination Dimensions >2s >2s >2s >2s 5mm www.tele-online.com ...