E1ZTP 230V AC TELE, E1ZTP 230V AC Datasheet - Page 2

no-image

E1ZTP 230V AC

Manufacturer Part Number
E1ZTP 230V AC
Description
STAIRCASE-TIMER
Manufacturer
TELE
Datasheet

Specifications of E1ZTP 230V AC

Impulse Relay (4 Ft.)
Contact Type
Time Range
0.5 To 12min
Svhc
No SVHC (18-Jun-2010)
Contact Current Max
16A
External Depth
60mm
External Length / Height
87mm
Mounting Type
DIN Rail
Output Type
Relay
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Functions
Function automatic timer (T, TW): After the pushbutton at B1 has been
pressed, the output relay R closes (terminals L-18) and the set interval
t begins. If the pushbutton is pressed again before the interval t has
expired, the interval begins again (restart function complies with EN
60669-2-3). Rapid, multiple pressing of the pushbutton (pumping) adds
2, 3 or more time intervals to extend the time up to 60min. Prolonged
pressure on the button (>2s) aborts the interval running and switches the
relay off (energy saving function). In the TW mode the device provides
a switch-off warning (in accordance with DIN 180-158-2) by generating
short pulses (flashing) at 30s, 15s and 5s prior to switch-off.
Operating possibilities at B1 in mode T and TW:
The additional control input C1-C2 can be used in the T and TW modes to
control the staircase lighting timer with a voltage of 8 to 230V AC/DC. This
input can be used to start and restart the cycle. It cannot be used for switch-
off (energy saving function) or for programming long intervals (pumping).
Impulse switch mode (P), (PN): n this mode, every keypress toggles
the output relay R (flip-flop). In function P, the output relay R remains in
off-position, whenever the supply voltage is applied. In function PN, the
output relay R switches into on-position after applying the supply voltage
U, if the output relay R was in on-position last before power failure. The
output relay R switches into on-position, if a short voltage impulse (<2s)
is applied to the additional control input (C1-C2). (central ON) A longer
voltage impulse (>2s) opens the output relay R. (central OFF)
Ordering Informations
RELEASE 2009/07
Subject to alterations and errors
Types
E1ZTP 230V AC
E1ZTPNC 230V AC
TW
Mode
Mode
PN
P
C1-C2
C1-C2
B1
R
B1
B1
U
R
U
R
t
>2s
15s
t
<2s
<2s
<2s
Switch ON
Retrigger
Time extension function (pumping)
Switch OFF
10s
>2s
>2s
Functiones
TW, 1, 0, P
T, TW, 1, 0, P, PN
2t
5s
T
>2s
<2s
<2s
<2s
3t
>2s
>2s
www.tele-online.com
>2s
>2s
Connections
3-wire-circuit
4-wire-circuit with attic illumination
Dimensions
5mm
Supply Voltage
230V AC
230V AC
8-230V
AC/DC
+
L
N
-
8-230V
AC/DC
+
L
N
44mm
60mm
-
18
B1
C1 C2
B1
18
18
B1
C1 C2
B1
18
N
L
L
N
L
N
L
N
Part. No.
110301
110300
17,5mm
E1ZT