HFBR-0564 Avago Technologies US Inc., HFBR-0564 Datasheet - Page 13

Fiber Optics, Evaluation Kit

HFBR-0564

Manufacturer Part Number
HFBR-0564
Description
Fiber Optics, Evaluation Kit
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of HFBR-0564

Silicon Manufacturer
Avago
Silicon Core Number
HFBR-591xE
Kit Application Type
Communication & Networking
Application Sub Type
MT-RJ Gigabit Ethernet Transceiver
Main Purpose
Interface, Ethernet
Embedded
No
Utilized Ic / Part
HFCT-591xE, HFBR-591xE
Primary Attributes
MT-RJ Gigabit, Multimode and Singlemode Applications
Secondary Attributes
MT-RJ Fiber Connector Interface
Operating Voltage
3.3 V
Description/function
Fiber Optic Kit
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
HFBR-591x, HFCT-591
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Contains lead / RoHS non-compliant
RECEIVER SIGNAL GROUND
Figure 15. Pin assignment diagram
Table 1. Pinout Table
Note:
1. The Transmitter and Receiver V
RECEIVER POWER SUPPLY
Pin
Two Mounting
Studs
Four Package
Grounding Tabs
1
2
3
4
5
6
7
8
9
10
RECEIVER DATA OUT BAR
RECEIVER DATA OUT
Symbol
V
V
SD
RD-
RD+
V
V
TDis
TD+
TD-
Grounding Tabs
SIGNAL DETECT
EER [1]
CCR
CCT
EET [1]
Package
Functional Description
The mounting studs are provided for transceiver mechanical attachment to the circuit board. They may
also provide an optional connection of the transceiver to the equipment chassis ground.
Note: The holes in the circuit board must be tied to chassis ground.
Note: Grounding tabs must be connected to signal ground for optimum EMI perfornance.
Receiver Signal Ground. Directly connect this pin to receiver signal ground plane.
Receiver Power Supply
Signal Detect
Normal Operation: Logic ‘1’ Output
Fault Condition: Logic ‘0’ Output
Received Data Out Bar
No internal terminations provided.
Received Data Out
No internal terminations provided.
Transmitter Power Supply
Transmitter Signal Ground
Transmitter Disable:
Transmitter Disabled: (V
Transmitter Enabled: V
Transmitter Data In
Transmitter Data In Bar
Connect to signal ground.
o
o
o
o
o
RX
1
2
3
4
5
EE
View
Top
connections are commoned within the module.
10
TX
9
8
7
6
o
o
o
o
o
EET
TRANSMITTER DATA IN BAR
TRANSMITTER DATA IN
TRANSMITTER DISABLE
TRANSMITTER SIGNAL GROUND
TRANSMITTER POWER SUPPLY
CCT
< V < (V
- 1.3 V) < V < V
Mounting Studs/
Solder Posts
EET
+ 0.8 V) or open circuit.
CCT
)