EP2SGX90EF1152I4 Altera, EP2SGX90EF1152I4 Datasheet - Page 64

Stratix II GX

EP2SGX90EF1152I4

Manufacturer Part Number
EP2SGX90EF1152I4
Description
Stratix II GX
Manufacturer
Altera
Datasheet

Specifications of EP2SGX90EF1152I4

Family Name
Stratix II GX
Number Of Logic Blocks/elements
90960
# I/os (max)
558
Frequency (max)
732.1MHz
Process Technology
SRAM
Operating Supply Voltage (typ)
1.2V
Logic Cells
90960
Ram Bits
4520448
Operating Supply Voltage (min)
1.15V
Operating Supply Voltage (max)
1.25V
Operating Temp Range
-40C to 100C
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
1152
Package Type
FC-FBGA
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP2SGX90EF1152I4
Manufacturer:
ALTERA
Quantity:
745
Part Number:
EP2SGX90EF1152I4
Manufacturer:
ALTERA
0
Part Number:
EP2SGX90EF1152I4
Manufacturer:
ALTERA
Quantity:
100
Part Number:
EP2SGX90EF1152I4N
Manufacturer:
ALTERA
Quantity:
535
Part Number:
EP2SGX90EF1152I4N
Manufacturer:
ALTERA
0
Part Number:
EP2SGX90EF1152I4N
Manufacturer:
ALTERA
Quantity:
100
Part Number:
EP2SGX90EF1152I4N
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
EP2SGX90EF1152I4N
0
Adaptive Logic Modules
Figure 2–41. ALM in Arithmetic Mode
2–56
Stratix II GX Device Handbook, Volume 1
datae0
datae1
dataf0
dataf1
datab
dataa
datad
datac
While operating in arithmetic mode, the ALM can support simultaneous
use of the adder’s carry output along with combinational logic outputs.
In this operation, the adder output is ignored. This usage of the adder
with the combinational logic output provides resource savings of up to
50% for functions that can use this ability. An example of such
functionality is a conditional operation, such as the one shown in
Figure
R = (X < Y) ? Y : X
To implement this function, the adder is used to subtract ‘Y’ from ‘X’. If
‘X’ is less than ‘Y’, the carry_out signal will be ‘1’. The carry_out
signal is fed to an adder where it drives out to the LAB local interconnect.
It then feeds to the LAB-wide syncload signal. When asserted,
syncload selects the syncdata input. In this case, the data ‘Y’ drives
the syncdata inputs to the registers. If ‘X’ is greater than or equal to ‘Y’,
the syncload signal is de-asserted and ‘X’ drives the data port of the
registers.
4-Input
4-Input
4-Input
4-Input
2–42. The equation for this example is:
LUT
LUT
LUT
LUT
carry_out
carry_in
adder0
adder1
D
D
reg0
reg1
Q
Q
To general or
To general or
To general or
To general or
local routing
local routing
local routing
local routing
Altera Corporation
October 2007

Related parts for EP2SGX90EF1152I4