KSZ8841-16MVLI Micrel Inc, KSZ8841-16MVLI Datasheet - Page 89

Single Ethernet Port + Generic (8, 16-bit) Bus Interface( )

KSZ8841-16MVLI

Manufacturer Part Number
KSZ8841-16MVLI
Description
Single Ethernet Port + Generic (8, 16-bit) Bus Interface( )
Manufacturer
Micrel Inc
Datasheets

Specifications of KSZ8841-16MVLI

Controller Type
Ethernet Controller, MAC
Interface
Bus
Voltage - Supply
3.1 V ~ 3.5 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
128-LQFP
Operating Supply Voltage (typ)
3.3V
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
128
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
576-1632 - BOARD EVALUATION KSZ8841-16MVL
Current - Supply
-
Lead Free Status / RoHS Status
Compliant, Lead free / RoHS Compliant
Other names
576-2114
KSZ8841-16MVLI

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
KSZ8841-16MVLI
Manufacturer:
MICREL
Quantity:
441
Part Number:
KSZ8841-16MVLI
Manufacturer:
Micrel Inc
Quantity:
10 000
Part Number:
KSZ8841-16MVLI-TR
0
Timing Specifications
Asynchronous Timing without using Address Strobe (ADSN = 0)
October 2007
Micrel, Inc.
Notes:
1.
2.
When CPU finished current Read or Write operation, it can do next Read or Write operation even the ARDY is low. During Read
or Write operation if the ADRY is low, the CPU has to keep the RDN/WRN low until the ARDY returns to high.
In order to speed up the ARDY low time to 40 ns, user has to use the turbo software driver which is only supported in the A6
device. Please refer to the “KSZ88xx Programmer's Guide” for detail.
Symbol
t1
t2
t3
t4
t5
t6
t7
t8
t9
t10
Addr, AEN, BExN
(Read Cycle)
( Write Cycle)
RDN, WRN
Write Data
Read Data
Parameter
A1-A15, AEN, BExN[3:0] valid to RDN, WRN active
A1-A15, AEN, BExN[3:0] hold after RDN inactive
(assume ADSN tied Low)
A1-A15, AEN, BExN[3:0] hold after WRN inactive
(assume ADSN tied Low)
Read data valid to ARDY rising
Read data to hold RDN inactive
Write data setup to WRN inactive
Write data hold after WRN inactive
Read active to ARDY Low
Write inactive to ARDY Low
ARDY low (wait time) in read cycle (Note1)
(It is 0ns to read bank select register and 40ns to
read QMU data register in turbo mode) (Note2)
ARDY low (wait time) in read cycle (Note1)
(It is 0ns to read bank select register and 80ns to
read QMU data register in normal mode)
ARDY low (wait time) in write cycle (Note1)
(It is 0ns to write bank select register)
(It is 36ns to write QMU data register)
ADSN
ARDY
ARDY
Table 16. Asynchronous Cycle (ADSN = 0) Timing Parameters
Figure 13. Asynchronous Cycle – ADSN = 0
t1
t7
89
t9
valid
t3
t5
valid
Min
0
0
1
4
4
2
0
0
0
valid
t2
t6
t4
t8
Typ
40
80
50
t10
KSZ8841-16/32 MQL/MVL/MBL
Max
0.8
8
8
Unit
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
M9999-102207-1.6