FLUKE-117 Fluke Electronics, FLUKE-117 Datasheet - Page 10

MULTMTR ELEC DMM W/NON CNT VOLT

FLUKE-117

Manufacturer Part Number
FLUKE-117
Description
MULTMTR ELEC DMM W/NON CNT VOLT
Manufacturer
Fluke Electronics
Series
VoltAlert™, 11xr
Type
Digital (DMM), Testerr
Datasheets

Specifications of FLUKE-117

Includes
Battery, Test Leads
Style
Handheld
Display Digits
3.75
Display Type
LCD, Bar Graph
Display Count
6000
Function
Voltage, Current, Resistance, Capacitance, Frequency
Functions, Extra
Continuity, Diode Test
Features
Backlight, Hold, Min/Max/Ave, Sleep
Ranging
Auto/Manual
Response
True RMS
Lead Free Status / RoHS Status
Vendor undefined / RoHS compliant by exemption
Other names
2538815
614-1011
114, 115, and 117
Users Manual
Battery Saver ("Sleep Mode")
The Meter automatically enters "Sleep mode" and blanks
the display if there is no function change, range change, or
button press for 20 minutes. Pressing any button or
turning the rotary switch awakens the Meter. To disable the
Sleep mode, hold down the g button while turning the
Meter on. The Sleep mode is always disabled in the MIN
MAX AVG mode.
MIN MAX AVG Recording Mode
The MIN MAX AVG recording mode captures the minimum
and maximum input values (ignoring overloads), and
calculates a running average of all readings. When a new
high or low is detected, the Meter beeps.
8
Put the Meter in the desired measurement function and
range.
Press p to enter MIN MAX AVG mode.
Mand MAX are displayed and the highest
reading detected since entering MIN MAX AVG is
displayed.
Press p to step through the low (MIN), average
(AVG), and present readings.
To pause MIN MAX AVG recording without erasing
stored values, press f. K is displayed.
To resume MIN MAX AVG recording, press fagain.
To exit and erase stored readings, press
least one second or turn the rotary switch.
p
for at
Display HOLD
In the Display HOLD mode, the Meter freezes the display.
1. Press fto activate Display HOLD. (K is
2. To exit and return to normal operation, press f or
Backlight
Press
automatically turns off after 40 seconds. To disable
backlight auto-off, hold down Q while turning the Meter
on.
Manual and Autoranging
The Meter has both Manual and Autorange modes.
displayed.)
turn the rotary switch.
In the Autorange mode, the Meter selects the range with
the best resolution.
In the Manual Range mode, you override Autorange and
select the range yourself.
Q
To avoid electric shock, when Display
HOLD is activated, be aware that the
display will not change when you
apply a different voltage.
to toggle the backlight on and off. The backlight
XWWarning