FLUKE-117 Fluke Electronics, FLUKE-117 Datasheet - Page 21

MULTMTR ELEC DMM W/NON CNT VOLT

FLUKE-117

Manufacturer Part Number
FLUKE-117
Description
MULTMTR ELEC DMM W/NON CNT VOLT
Manufacturer
Fluke Electronics
Series
VoltAlert™, 11xr
Type
Digital (DMM), Testerr
Datasheets

Specifications of FLUKE-117

Includes
Battery, Test Leads
Style
Handheld
Display Digits
3.75
Display Type
LCD, Bar Graph
Display Count
6000
Function
Voltage, Current, Resistance, Capacitance, Frequency
Functions, Extra
Continuity, Diode Test
Features
Backlight, Hold, Min/Max/Ave, Sleep
Ranging
Auto/Manual
Response
True RMS
Lead Free Status / RoHS Status
Vendor undefined / RoHS compliant by exemption
Other names
2538815
614-1011
General Specifications
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 C to 28 C, with
relative humidity at 0 % to 90 %.
Extended specifications are available at www.Fluke.com.
Maximum voltage between any
terminal and earth ground ...................................... 600 V
Surge Protection ..................................................... 6 kV peak per IEC 61010-1 600V CAT III,
W Fuse for A input (115 & 117 only): .................... 11 A, 1000 V FAST 17 kA Fuse (Fluke PN 803293)
Display ..................................................................... Digital: 6,000 counts, updates 4/sec
Temperature............................................................. Operating: -10 °C to + 50 °C
Temperature Coefficient ......................................... 0.1 x (specified accuracy)/ C (<18 C or >28 C)
Operating Altitude ................................................... 2,000 meters
Battery
Battery Life............................................................... Alkaline: 400 hours typical, without backlight
Safety Compliances ................................................ Complies with ANSI/ISA 82.02.01 (61010-1) 2004,
....................................................................... 9 Volt Alkaline, NEDA 1604A / IEC 6LR61
Pollution Degree 2
Bar Graph: 33 segments, updates 32/sec
Storage: -40 °C to + 60 °C
CAN/CSA-C22.2 No 61010-1-04, UL 6101B (2003)
and IEC/EN 61010-1 2
Category III, 600 V, Pollution Degree 2, EMC
EN61326-1
nd
True-rms Multimeters
Edition for measurement
General Specifications
19