Specifications of 8808A/SU 120V

Includes
Test Leads
Style
Bench
Display Digits
5.5
Display Type
VFD, Dual
Display Count
200000
Function
Voltage, Current, Resistance, Frequency
Functions, Extra
Continuity, dB, Diode Test
Features
Hold, Min/Max, RS-232 Port
Ranging
Auto/Manual
Response
True RMS
Lead Free Status / RoHS Status
Not applicable / RoHS non-compliant
Other names
614-1069
8808A
Users Manual
2-6
1. Remove power from the Meter by unplugging its power cord.
2. Turn the Meter upside down.
3. Remove the retaining screw on the fuse access door located on the bottom of the
4. Remove the protective cover from the fuse holders by slightly depressing the
5. Remove the defective fuse and replace it with a fuse of an appropriate rating. See
6. Replace the protective cover by pushing it over the fuses while aligning the
7. Replace the fuse access door and install the retaining screw.
Meter. See Figure 2-2.
back edge of the cover to unlatch it from the printed circuit board. Pull up on the
back edge of the cover and remove it from the fuse compartment.
Table 2-1.
catches with the holes in the printed circuit board. Press the cover down until the
catches engage the printed circuit board.
Figure 2-2. Replacing the Current-Input Fuses
Fuses
F1
F2
Bottom front
left corner
eue04.eps