8846A/SU 120V Fluke Electronics, 8846A/SU 120V Datasheet - Page 60

PREC MLTMTR 6.5DIGI USB W/SFTWRE

8846A/SU 120V

Manufacturer Part Number
8846A/SU 120V
Description
PREC MLTMTR 6.5DIGI USB W/SFTWRE
Manufacturer
Fluke Electronics
Type
Digital (DMM)r
Datasheets

Specifications of 8846A/SU 120V

Includes
Test Leads
Style
Bench
Display Digits
6.5
Display Type
VFD, Dual
Display Count
Varies
Function
Voltage, Current, Resistance, Capacitance, Temperature, Frequency
Functions, Extra
Continuity, dB, Diode Test
Features
Memory, RS-232, USB Port
Ranging
Manual
Response
Average
Lead Free Status / RoHS Status
Contains lead / RoHS compliant by exemption
Other names
2675344
614-1003
8845A/8846A
Users Manual
3-18
Setting the Number of Samples
Understanding the Measurement Complete Signal
Accessing and Controlling Memory
Storing Readings in Memory
4. To select a specific digit to adjust, press either <-- or -->.
5. With the desired delay set, press the soft key labeled ENTER.
Normally, the Meter takes one measurement (or sample) each time a trigger is received if
in “wait-for-trigger” state. However, you can set the Meter to take a specified number of
measurements for each trigger.
To set the number of samples per trigger:
1. Press L.
2. Press the soft key labeled TRIGGER.
3. Press the soft key labeled #SAMPLES.
4. To select a specific digit to adjust, press either <-- or -->.
5. With the desired delay set, press the soft key labeled ENTER.
The trigger port on the Meter’s back panel provides a low-true pulse at the completion of
each Meter measurement. See the specifications section for more details on this signal.
The Meter stores readings and meter configuration information using internal and
external memory (8846A only). On the 8846A, external memory connects through the
USB port on the front panel of the Meter. Optional Memory in various storage capacities
is available from Fluke. See the “Options and Accessories” section in Chapter 1 for Fluke
part numbers. In addition to storing and recalling readings and configurations, a memory
management function is available to delete files.
To access the Memory functions, press the M key. The memory menu appears over
the five soft keys: RECALL CONFIG, RECALL READING, STORE CONFIG,
STORE READINGS, and MANAGE MEMORY.
The Meter will hold up to 9999 readings in one internal memory file. The 8846A, with
external memory, will hold 999 additional readings files, each of which will store up to
10000 readings.
To store readings in internal memory:
1. Press M.
With the desired digit selected, press the soft key labeled -- to decrement the digit
or ++ to increment the digit.
The number of samples per trigger can be set between 0 and 50000 samples.
With the desired digit selected, press the soft key labeled -- to decrement the digit
or ++ to increment the digit.