ACDC-620T Amprobe, ACDC-620T Datasheet - Page 20

DMM CLAMP-ON TRMS

ACDC-620T

Manufacturer Part Number
ACDC-620T
Description
DMM CLAMP-ON TRMS
Manufacturer
Amprobe
Type
Digital (DMM)r
Datasheet

Specifications of ACDC-620T

Includes
Battery, Case, Test Leads
Style
Clamp
Display Digits
4
Display Type
LCD, Bar Graph
Display Count
4000
Function
Voltage, Current, Resistance, Capacitance, Temperature
Functions, Extra
Continuity, Diode Test
Features
Auto Off, Hold, Min/Max/Ave, Sleep
Ranging
Auto/Manual
Response
True RMS
Frequency
45 Hz to 65 Hz
Maximum Ac Current
1 KA
True Rms
Yes
Voltage
400 V/100 V
Lead Free Status / RoHS Status
Contains lead / RoHS compliant by exemption
Other names
2730822
This clamp-on multimeter provides the operator with various functions including:
c
c
c
c
c
c
c
c
c
c
The dynamic recording mode can be used to catch intermittent and turn on or off
surges, verify performance while you are away, or take readings while you are
operating the equipment under test and can not watch the meter.
the average reading is useful for smoothing out unstable or changing inputs, esti-
mating the the percent of time a circuit is operational, or verifying circuit perform-
ance
The operational procedures are described below::
1. Press and hold the "MAX MIN" push button to toggle recording mode on or
2. Press this button momentarily to cycle through maximum, average and present
Dynamic Recording
Data Hold
Zero (Relative)
Analog bargraph
Auto Power Off and Sleep Mode
Disable Auto Power Off
Demonstrate Annunciator of Display
Continuity Function For Ohms Measurement
1ms Peak hold
DYNAMIC RECORDING
off. the dynamic recording ode is indicated when the MAX AVG MIN annunci
ator turns on. The present valve is stored to memories of maximum, minimum
and average.
readings. The MAX, MIN, AVG annunciator turns on respectively to indicate
what value is being displayed. See Figure 7.
SPECIALFUNCTIONS INSTRUCTIONS
19