ACDC-620T Amprobe, ACDC-620T Datasheet - Page 30

DMM CLAMP-ON TRMS

ACDC-620T

Manufacturer Part Number
ACDC-620T
Description
DMM CLAMP-ON TRMS
Manufacturer
Amprobe
Type
Digital (DMM)r
Datasheet

Specifications of ACDC-620T

Includes
Battery, Case, Test Leads
Style
Clamp
Display Digits
4
Display Type
LCD, Bar Graph
Display Count
4000
Function
Voltage, Current, Resistance, Capacitance, Temperature
Functions, Extra
Continuity, Diode Test
Features
Auto Off, Hold, Min/Max/Ave, Sleep
Ranging
Auto/Manual
Response
True RMS
Frequency
45 Hz to 65 Hz
Maximum Ac Current
1 KA
True Rms
Yes
Voltage
400 V/100 V
Lead Free Status / RoHS Status
Contains lead / RoHS compliant by exemption
Other names
2730822
c
WARNING: MAKE CERTAIN THATALLTESTLEADS ARE DISCONNECTED
1 ) Set the rotary switch to " A ".
2) Open the meter jaws and clamp around a single conductor. The most accurate
3) Read the display.
reading will be obtained by keeping the conductor aligned with the centering
marks on the jaws. Make sure that the jaws are fully closed.
AC CURRENT MEASUREMENT
FROM THE METER TERMINALS.
HOW TO OPERATE
29