A165E-M-03U Omron, A165E-M-03U Datasheet - Page 122

E-stop,non-lighted,40diameter

A165E-M-03U

Manufacturer Part Number
A165E-M-03U
Description
E-stop,non-lighted,40diameter
Manufacturer
Omron
Datasheets

Specifications of A165E-M-03U

Contact Configuration
3PST-NC
Switch Operation
Pushlock Turn Reset
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
30V
Contact Current Max
5A
Actuator Style
Round
Control Type
Emergency Stop
Contact Form
3PST - NC
Contact Rating
10 mAmps
Illuminated
N
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Installation
After installing the Operation Unit, snap in the Switch from the back of the panel.
1. Installing the Switch
Attach rubber packing or the Yellow Plate onto the Switch from its terminal side. Insert the Switch into the panel from the front. Install the lock ring
and mounting nut from the terminal side and tighten.
Adjust the slits on the hole of rubber packing and Yellow Plate to the protruding part of the Unit.
Rubber packing is not necessary when the Yellow Plate is used.
Tighten the nut to the torque of 0.29 to 0.49 N·m.
Casing should be installed with its protruding part adjusted to the slit of the panel hole.
Align the lock ring to the groove of the casing so that the edge is drawn to the panel side.
2. Mounting the Switch
Snap on the Switch to the Operation Unit.
Make sure that the Switch has the correct orientation when snapping
it onto the Operation Unit. Align the white dot on the Operation Unit
with the guide groove on the side of the Switch marked with an “L” as
shown below, and push the Switch into the Operation Unit until it
clicks into place. Confirm that the Switch is securely in place before
using.
120
Mounting to the Panel
Lock hole
Cutout
Lock
White dot
Guide groove
Mounting nut
Rubber packing
(included with the
product) or Yellow
Plate (sold separately)
Lock ring
Panel
L marking
3. Removing the Switch
Insert the prongs of the A16Z-5080 Extractor between the Switch
and the Operation Unit, grip the Switch, and pull to remove.
4. Installing the LED Lamp
When mounting the Lamp, make sure it is facing the direction shown
in the following diagram. Insert the Lamp while matching the protrud-
ing part of the Lamp and the small guides on the outer surface of the
casing.
Rubber packing or Yellow Plate (sold separately)
Protruding part
Panel
Edge
Wide guide
Extractor
(A16Z-5080)
Mounting nut
Narrow guide
Lock ring