A165E-M-03U Omron, A165E-M-03U Datasheet - Page 41

E-stop,non-lighted,40diameter

A165E-M-03U

Manufacturer Part Number
A165E-M-03U
Description
E-stop,non-lighted,40diameter
Manufacturer
Omron
Datasheets

Specifications of A165E-M-03U

Contact Configuration
3PST-NC
Switch Operation
Pushlock Turn Reset
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
30V
Contact Current Max
5A
Actuator Style
Round
Control Type
Emergency Stop
Contact Form
3PST - NC
Contact Rating
10 mAmps
Illuminated
N
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
A3C
Note: 1. With alternate-operation models, one operation cycle consists of set and reset operations.
Note: The value for LTA min. applies to alternate-operation mod-
Operating frequency
Insulation resistance
Dielectric strength
Vibration
Shock
Life expectancy
Weight
Ambient operating temperature
Ambient operating humidity
Ambient storage temperature
Degree of protection
Electric shock protection class
PTI (proof tracking index)
Pollution degree
OF max.
RF min.
TT
LTA min.
(See note.)
PT max.
SPDT
Contact name
Characteristics
Operating Characteristics
Contact Form
2. The figure given above for the dielectric strength between lamp terminals is for when there is no LED lamp or incandescent lamp
3. The weight indicated here applies to the lighted models (SPST-NO+SPST-NC).
els only.
mounted.
2.45 N
0.29 N
Approx. 3.5 mm
0.5 mm
2.5 mm
NO
NC
Contact form
Mechanical:
Electrical: 20 operations/minute max.
100 MΩ min. (at 500 VDC)
1,000 VAC, 50/60 Hz for 1 minute between terminals of same polarity and between lamp
terminals (See note 2.)
2,000 VAC, 50/60 Hz for 1 minute between terminals of different polarity and also between
each terminal and ground
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude (No malfunctions for more than 1 s.)
Destruction: 500 m/s
Malfunction: 150 m/s
Mechanical:
Electrical: 100,000 operations min.
Approx. 5 g (See note 3.)
–10°C to 55°C (with no icing or condensation)
35% to 85%
–25°C to 65°C
IP40
Class II
175
3 (IEC947-5-1)
Momentary-action models: 120 operations/minute max.
Alternate-action models: 60 operations/minute max. (See note 1.)
Momentary-action models: 1,000,000 operations min.
Alternate-action models: 100,000 operations min. (See note 1.)
NO
NC
2
2
(No malfunctions for more than 1 s.)
UL (File No. E41515)
CSA (File No. LR45258-31)
Rating
Standard
1 A at 125 VAC
0.5 A at 250 VAC
1 A at 30 VDC
Microload
0.1 A at 125 VAC
0.1 A at 30 VDC
Approved by Standards
A3C
39

Related parts for A165E-M-03U