A165E-M-03U Omron, A165E-M-03U Datasheet - Page 25

E-stop,non-lighted,40diameter

A165E-M-03U

Manufacturer Part Number
A165E-M-03U
Description
E-stop,non-lighted,40diameter
Manufacturer
Omron
Datasheets

Specifications of A165E-M-03U

Contact Configuration
3PST-NC
Switch Operation
Pushlock Turn Reset
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
30V
Contact Current Max
5A
Actuator Style
Round
Control Type
Emergency Stop
Contact Form
3PST - NC
Contact Rating
10 mAmps
Illuminated
N
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
A3D
Specifications
Contact Rating: 30 VDC, 0.1 A (Minimum Appli-
cable Load: 5 VDC, 1 mA)
The above ratings conform to JIS C4505, for testing under the fol-
lowing conditions.
Built-in LED Lamp
Note: 1. The above ratings are for an ambient temperature of 25°C.
Note: 1. With alternate operation models, 60 operations/minute max. One operation cycle consists of set and reset operations.
Forward voltage, V
Forward current, I
Permissible dissipation, PD
Reverse voltage, V
Operating frequency
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Life expectancy
Weight
Ambient operating temperature
Ambient operating humidity
Ambient storage temperature
Degree of protection
Electric shock protection class
PTI (proof tracking index)
Pollution degree
Ratings
Characteristics
2. The built-in LED lamp has no limiting resistor and so it is necessary to connect an external resistor within the range shown in the
3. Refer to the characteristic graphs of V
4. The same LED lamp is used for both yellow illumination and white illumination and so the ratings are the same.
2. The figure for dielectric strength between lamp terminals is for when the LED lamp is not mounted.
3. “Malfunction” in the above table indicates malfunctions of less than 1 ms.
above table. (For details of calculation formulas, refer to page 28.)
g ,
,
g
F
F
F
F
R
Item
Reference value (See note 3.)
Maximum value
Reference value
Absolute maximum value
Absolute maximum value
Absolute maximum value
Mechanical: 120 operations/minute max. (See note 1.)
Electrical: 20 operations/minute max.
100 MΩ min. (at 500 VDC)
1,000 VAC, 50/60 Hz for 1 minute between terminals of same polarity
2,000 VAC, 50/60 Hz for 1 minute between terminals of different polarity, and between each
terminal and ground
1,000 VAC, 50/60 Hz for 1 minute between lamp terminals (See note 2.)
Malfunction: 10 to 55 Hz, 1.5 mm double amplitude (See note 3.)
Destruction: 500 m/s
Malfunction: 150 m/s
Mechanical:
Momentary operation models: 1,000,000 operations min.
Alternate operation models: 100,000 operations min.
(One operation consists of set and reset operations.)
Electrical: 100,000 operations min.
Approx. 3 g
–10_C to 55_C (with no icing or condensation)
35% to 85%
–25_C to 65_C
IP40
Class II
175
3 (IEC947-5-1)
F
– I
F
on page 24.
2
2
(See note 3.)
1.7 V
2.0 V
20 mA
50 mA
100 mW
4 V
1. Load: Resistive load
2. Mounting conditions: No vibration or shock
3. Ambient temperature: 20 $2_C.
4. Operating frequency: 20 times/min.
Red
2.2 V
2.5 V
20 mA
50 mA
125 mW
4 V
Yellow (White)
(See note 4.)
Color
2.1 V
2.5 V
20 mA
50 mA
122 mW
4 V
Green
A3D
23