DRT2-MD16S Omron, DRT2-MD16S Datasheet - Page 316

no-image

DRT2-MD16S

Manufacturer Part Number
DRT2-MD16S
Description
DRT2 Mix IO E-Con8 In/out, NPN
Manufacturer
Omron
Datasheet

Specifications of DRT2-MD16S

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
7-1-3
DRT2-AD04/DRT2-AD04H Analog Input Terminals
Overview of Analog Slaves
Unit power supply
Communications power sup-
ply current consumption
Connections
Data allocated in Master
Node address setting
Baud rate setting
Moving average
Off-wire (disconnection)
detection
Scaling, offset compensation,
peak/bottom hold, top/valley
hold, rate of change opera-
tions, comparator
Mainte-
nance
functions
Moving average
Setting the number of AD
conversion points
(DRT2-AD04 only)
Function
User adjustment
Cumulative counter
Last maintenance
date
Input temperature
variation detection
function
Temperature inte-
gration function
Top/Valley count
function
Temperature range
timing function
List of Data Processing Functions
Slave
Note The input accuracy depends on the mounting method. For details, refer to the
Calculates the average of the past eight analog input val-
ues, and produces a stable input value even when the input
value is unsteady.
By reducing the number of input conversion points, the con-
version cycle speed can be increased. For details, refer to
7-4-4 Calculating the Conversion Cycle (DRT2-AD04 Only).
Supplied by local power supply terminal.
30 mA max.
Poll, Bitstrobe
Just temperature data for 4 inputs
Set using the DIP switch.
Set using the DIP switch.
Not supported.
Supported.
Not supported.
Performance Specifications in 7-6-1 DRT2-TS04T and DRT2-TS04P Temper-
ature Input Terminals.
The following tables list the data processing functions that can be used with
Analog Slaves. Refer to 7-4-3 Functions and Settings for details on functions
and setting methods.
DRT1 Series
Details
Supplied by communications power supply.
70 mA max.
Poll, Bitstrobe, COS/cyclic
Default: Temperature data for 4 inputs
The following data items can be allocated
by making additional Configurator settings:
Peak value, Bottom value, Top value, Valley
value, Rate-of-change value, Comparator
result; Generic Status Flags, etc.
Set using the rotary switches or the Config-
urator.
Automatically detected: Uses the baud rate
set for the Master Unit.
Supported. (Set using Configurator.)
Supported. (Set using Configurator.)
Moving average disabled.
4-point conversion
DRT2 Series
Default
Section 7-1
295