DRT2-MD16S Omron, DRT2-MD16S Datasheet - Page 399

no-image

DRT2-MD16S

Manufacturer Part Number
DRT2-MD16S
Description
DRT2 Mix IO E-Con8 In/out, NPN
Manufacturer
Omron
Datasheet

Specifications of DRT2-MD16S

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Temperature Input Terminals
Performance Specifications
Effects of Mounting
Direction on Indicator
Accuracy
378
Terminal strength
Weight
Model
Input type
Indicator accuracy
Conversion cycle
Temperature conversion
data
Isolation method
Item
Item
Note
Pulling: 50 N
160 g max.
DRT2-TS04T
Switchable between R, S, K1, K2, J1, J2, T, B,
L1, L2, E, U, N, W, and PL2
When set with Configurator: Input types can
be set individually for each input.
Wen set with DIP switch: The same input type
setting applies to all 4 inputs.
(
is larger)
(See note 2.)
250 ms/4 points
Hexadecimal data (4-digit hexadecimal when normal display mode is selected or 8-digit hexa-
decimal when 1/100 display mode is selected.)
Between input and communication lines: Photocoupler isolation
Between temperature input signals: Photocoupler isolation
±
Indicator Accuracy in Exceptional Cases
K1, K2, T, and N below
− 100 ° C
U, L1, and L2
R and S below 200 ° C
B below 400 ° C
W
PL2
0.3% of indication value or
temperature range
Input type and
1. A current of 0.35 mA flows to sensors connected to the DRT2-TS04P.
2. The indicator accuracy specifications differ depending on the mounting di-
In the DRT2-TS04T, a cold junction compensator is included in the Terminal
Block. The indicator accuracy will be reduced depending on the mounting
direction if just the Terminal Unit itself is replaced and the serial numbers of
the Terminal Block and Terminal Unit do not match. The serial numbers of the
Terminal Block and Terminal Unit can be found on the labels affixed to the
Units as shown below.
±
1 digit max.
rection. Refer to the above table for details.
Terminal Unit Label
Remove the terminal block. The label is attached
to the Unit under the terminal block.
±2°C ±1 digit max.
±2°C ±1 digit max.
±3°C ±1 digit max.
Not specified.
±0.3% of indication value or
±3°C (whichever is larger) ±1
digit max.
±0.3% of indication value or
±2°C (whichever is larger) ±1
digit max.
Input accuracy
±
1°C, whichever
Specifications
Specifications
160 g max.
DRT2-TS04P (See note 1.)
Switchable between PT, JPT, PT2, and JPT2
When set with Configurator: Input types can
be set individually for each input.
Wen set with DIP switch: The same input type
setting applies to all 4 inputs.
−200 to 850°C input range:
(
ever is larger)
−200 to 200°C input range:
(
ever is larger)
±
±
0.3% of indication value or
0.3% of indication value or
±
±
1 digit max.
1 digit max.
Terminal Block Label
The label is attached to the
back of the terminal block.
±
±
Section 7-6
0.8°C, which-
0.5°C, which-

Related parts for DRT2-MD16S