Installation (continued)
Connecting the Controller to a
Network
network, attach the appropriate RG62A/U coaxial cable to the
M4SARC card’s BNC-style connector.
Setting ARCNET Host Port Jumpers
card, change controller jumper settings to match those shown in
the table below.
card to operate. Verify your jumper settings carefully before turning
on the controller.
is used for ARCNET communication when the controller is powered
up or reset. Only the lowest numbered ARCNET port in the controller
can be a host port. For example, if an M4SARC coaxial ARCNET
card and an M4DUALARC twisted-pair card are both installed in a
controller (with host port jumpers set for ARCNET), the coaxial
ARCNET port on the M4SARC card will be the host port because
it has the lowest ARCNET port number (4).
ARCNET, but an ARCNET card is not installed, COM0 will be the
host port by default.
Controller Jumper Settings
for ARCNET Host Port
COM0
COM1
ARCNET
Ethernet
To connect the M4-family controller to an Opto 22 controller
To configure your controller to use the M4SARC interface
Warning: Jumpers must be set correctly for the M4SARC
The host jumpers on the controller determine which host port
If an M4-family controller has jumper settings configured for
© 2004 Opto 22. All rights reserved. All trademarks, trade names, logos, and service marks referenced herein belong to their respective companies.
Inside Sales: (800) 321-OPTO • Product Support: (800) TEK-OPTO • (951) 695-3080 • Fax: (951) 695-3017 • Email: sales@opto22.com
All M4-Family
Out
Out
H0
Controllers
In
In
Jumpers
Out
Out
H1
In
In
Setting an ARCNET Node Address
controller on the network must have a unique node address between
1 and 255. The node address is set using the controller’s address
jumpers. See the user’s guide for your controller for specific
information on configuring address jumpers.
Recommended ARCNET Networking
Hardware
components from the following manufacturer:
Contemporary Control Systems’ ARCNET equipment with Opto 22
products, or contact Opto 22 Product Support. Contact information
appears at the bottom of the page.
To communicate on an ARCNET network, each M4-family
Opto 22 recommends ARCNET cards and networking
Contemporary Control Systems, Inc. (CCSI)
2431 Curtiss Street
Downers Grove, IL 60515
Phone: (630) 963-7070
FAX: (630) 963-0109
E-mail: info@ccontrol.com
Web: www.ccontrol.com (or www.ccontrols.com)
See Opto 22 form 1294 for more information about using
INTERFACES
CONTROLLERS
MODULAR
page 6/7

Related parts for M4SARC