FLUKE-287 CALIBRATED Fluke, FLUKE-287 CALIBRATED Datasheet - Page 18

MULTIMETER, DIGITAL, HANDHELD

FLUKE-287 CALIBRATED

Manufacturer Part Number
FLUKE-287 CALIBRATED
Description
MULTIMETER, DIGITAL, HANDHELD
Manufacturer
Fluke
Datasheet

Specifications of FLUKE-287 CALIBRATED

Dmm Type
Handheld
Voltage Measuring Range Dc
50 MV To 50 V
Voltage Measuring Range Ac
500 V To 1000 V
Current Measuring Range Dc
500µA To 10A
Current Measuring Range Ac
500µA To 10A
Lead Free Status / RoHS Status
na
287/289
Users Manual
8
Item
J
K
L
M
N
O
P
Mini-
measurement
Date
Beeper
Units
Auxiliary Units
Range indicator
Secondary display Displays secondary measurement
Function
Table 3. Display Features (cont.)
Displays the lightning bolt (when
necessary) and the input value
when the primary and secondary
displays are covered by a menu or
pop-up message.
Indicates the date set in the internal
clock.
Indicates the Meter’s beeper is
enabled (not associated with the
continuity beeper).
Indicates the units of measure.
Indicates unitless measurements
like Crest Factor.
Indicates the range the Meter is in
and the ranging mode (auto or
manual).
information about the input signal.
Indication
Bar Graph
The analog bar graph functions like the needle on an analog
meter, but without the overshoot. The bar graph updates 30
times per second. Because the graph updates faster than the
digital display, it is useful for making peak and null adjustments
and observing rapidly changing inputs. For frequency, duty cycle,
pulse width, dBm, and crest factor functions, the bar graph
represents the amplitude of the input signal (volts or amps) and
not the value in the primary display. The bar graph is not shown
for capacitance, temperature, LoZ, AC+DC, AC over DC, peak,
or min max functions.
For dc voltage, dc current, and all relative percent modes, a
zero-centered bar graph is displayed. For dc voltage and current,
the bar graph range is the maximum of the selected range. For
relative percent mode, the bar graph goes to 10 %.
The number of lit segments indicates the measured value and is
relative to the full-scale value of the selected range. In the 50
Vac range, for example, the major divisions on the scale
represent 0, 5, 10, 15, 20, 25, 30, 35, 40, 45, and 50 Vac. An
input of 25 Vac turns on segments up to the middle of the scale.
For off-scale values,
graph. For the zero-center bar graph, a
of the bar graph for negative off-scale values and
the right end for positive off-scale values.
Status Bar Elements
The status bar at the top of the Meter’s display contains
indicators for battery level, time of day, mini-measurement
display, present date, and beeper on/off icon.
appears to the right of the normal bar
appears at the left end
appears on