FLUKE-287 CALIBRATED Fluke, FLUKE-287 CALIBRATED Datasheet - Page 65

MULTIMETER, DIGITAL, HANDHELD

FLUKE-287 CALIBRATED

Manufacturer Part Number
FLUKE-287 CALIBRATED
Description
MULTIMETER, DIGITAL, HANDHELD
Manufacturer
Fluke
Datasheet

Specifications of FLUKE-287 CALIBRATED

Dmm Type
Handheld
Voltage Measuring Range Dc
50 MV To 50 V
Voltage Measuring Range Ac
500 V To 1000 V
Current Measuring Range Dc
500µA To 10A
Current Measuring Range Ac
500µA To 10A
Lead Free Status / RoHS Status
na
Item
6
5
A
B
C
D
E
F
Table 9. Stopped Recording Display
Stopped Icon indicating the recording session is
stopped.
Time and date when the recording began.
Length (duration) of time recording session was
in progress.
Number of event records detected.
Reference value for relative measurements.
Number of interval records detected.
0
Start Time :
8:10pm
Duration : 3 days 14 Hrs 47 mins
Interval Samples: 135
Reference: 121.70 VAC
REL
100
Save
1.75
200
06/10/07 07:23:55
123.45 VAC
Description
300
Stopped
Trend
Events:53
400
VAC
06/13/07
Auto Range
1
Recording
Close
500 VAC
est34.eps
2
3
4
Using Communications
You can use the IR communication link and FlukeView Forms
software to transfer the contents of a meter’s memory to a PC.
When using a PC-to-meter IR (infrared) communication link, refer
to the FlukeView Forms Installation Guide or the on-line help.
FlukeView Forms allows you to place the data into standard
(default) or customized forms. The forms display the data in table
and graph form, as well as show user comments. You can use
these forms to satisfy ISO-9000 and other documentation
requirements.
The Meter will log in real-time mode to a connected
computer running FlukeView Forms. In addition, the
Meter allows the user to log to internal memory and
connect to the computer later for download.
Note
Using Communications
55