FLUKE-287 CALIBRATED Fluke, FLUKE-287 CALIBRATED Datasheet - Page 63

MULTIMETER, DIGITAL, HANDHELD

FLUKE-287 CALIBRATED

Manufacturer Part Number
FLUKE-287 CALIBRATED
Description
MULTIMETER, DIGITAL, HANDHELD
Manufacturer
Fluke
Datasheet

Specifications of FLUKE-287 CALIBRATED

Dmm Type
Handheld
Voltage Measuring Range Dc
50 MV To 50 V
Voltage Measuring Range Ac
500 V To 1000 V
Current Measuring Range Dc
500µA To 10A
Current Measuring Range Ac
500µA To 10A
Lead Free Status / RoHS Status
na
Setting up a Recording Session
Before starting a recording session, setup the Meter for the
measurements to be recorded. If needed, change the event
threshold value (see the “Setting the Event Threshold Value
section later in this manual). Press the softkey labeled Save to
open the save menu. Using the cursor buttons, move the menu
selector next to the menu item labeled Record and press the
softkey labeled Record to open the configuration display.
There are two variables in setting up a recording session:
Recording session duration, and sample interval duration. Both
variables affect the recording length and number of intervals
recorded. These two variables may interact, in that setting one
variable may adjust the other variable to fit the recording session
within the available memory. The percentage of memory
available at the beginning of a recording session is displayed
below the duration and sample interval settings. Option values
can be adjusted as follows:
The sample interval can be set from one second to 99 minutes
and 59 seconds. Recording session duration can be set from one
minute to 99 days 23 hours 59 minutes.
Recording session duration expiring.
Manually stopping the recording session.
Item
6
5
A
B
C
D
E
F
Recording session in progress icon.
Time and date when recording session started.
Time remaining until recording session stops.
Total number of event records recorded so far.
Reference value for relative measurements.
Total number of interval records recorded so far.
0
Start Time:
8:10pm
Remaining Time: 2 Hrs 26 mins
Interval Samples: 47
Reference: 121.70 VAC
Table 8. Recording Display
100
1.75
200
06/10/07 07:23:55
123.45 VAC
Description
Recording Measurement Data
300
Events:7
400
VAC
06/13/07
Auto Range
Recording
Stop
500 VAC
est31.eps
1
2
3
4
53