MAX3543CTL+ Maxim Integrated Products, MAX3543CTL+ Datasheet - Page 11

no-image

MAX3543CTL+

Manufacturer Part Number
MAX3543CTL+
Description
RF Receiver Multi-band Ananlog a and Digital TV Tuner
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX3543CTL+

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Table 4. R00: VCO Register—VCO and LO Divider Control (Address: 00h)
Table 5. R01: NDIV INT Register—Integer Part of N-Divider (Address: 01h)
Table 6. R02: NDIV FRAC2 Register—N-Divider Fractional Part [19:16] and R-Divider
(Address: 02h)
BIT NAME
VSUB[3:0]
BIT NAME
VDIV[1:0]
VCO[1:0]
RDIV[1:0]
NINT[7:0]
F[19:16]
NAME
CPS
BIT
CP
BIT LOCATION
BIT LOCATION
BIT LOCATION
(0 = LSB)
(0 = LSB)
(0 = LSB)
______________________________________________________________________________________
7:6
5:2
1:0
5:4
3:0
7:0
7
6
SETTING
TYPICAL
TYPICAL
SETTING
TYPICAL
SETTING
0011
1110
0010
1011
01
00
00
1
0
VCO select. Selects one of three VCOs when VAS = 0, or selects the VCO starting
band when VASS = 0.
00 = Selects VCO1 (approximately 2200MHz to 2800MHz)
01 = Selects VCO2 (approximately 2800MHz to 3500MHz)
10 = Selects VCO3 (approximately 3500MHz to 4400MHz)
11 = VCO shutdown
VCO sub-band select. Selects one of 16 possible VCO sub-bands when VAS = 0,
or selects the VCO starting sub-band when VASS = 0.
0000 = Selects SB0
1111 = Selects SB15
VCO divider ratio select.
00 = Sets VCO divider to 4 (use when f
01 = Sets VCO divider to 8 (use when 275MHz < f
10 = Sets VCO divider to 16 (use when 137.5MHz < f
11 = Sets VCO divider to 32 (use when f
Sets the charge-pump current-selection mode between automatic and manual.
Must set to 1 for proper operation.
For Maxim use only
Reference divider.
00 = /1
01 = /2
1X = Maxim use only
N-divider fractional part bits 19:16 (out of 19:0)
Sets the PLL integer divide number (N)
Digital Television Tuner
Multiband Analog and
FUNCTION
FUNCTION
FUNCTION
LO
LO
> 550MHz)
Register and Bit Descriptions
< 137.5MHz)
LO
LO
< 550MHz)
< 275MHz)
11

Related parts for MAX3543CTL+