Specifications of 2-1419130-4

Contact Arrangement
SPDT
Dc Coil Voltage
12 V
Coil Current
12.5 mA
Mounting
Through Hole
Relay Construction
Non-Latching
Coil Voltage Dc
12V
Contact Form
1 Form C
Coil Resistance
960Ohm
Contact Current Rating
1A
Contact Material
Silver Nickel/Gold Plated
Coil Suppression Diode
No
Push To Test Button
No
Led Indicator
No
Seal
Sealed
Product Height (mm)
10mm
Product Depth (mm)
7.5mm
Product Length (mm)
12.5mm
Mounting Style
Through Hole
Termination Style
PC Pin
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
2-1419130-4
Manufacturer:
TE
Quantity:
39 178
Part Number:
2-1419130-4
Manufacturer:
TE/AMP
Quantity:
35 000
Input Data
Nominal Voltage:
Maximum Voltage: 132VAC for the 110 to 120VAC model;
Frequency: 50/60 Hz.
Power Requirement: 750mW.
Transient Noise Immunity: ICS 2-230, ANSI C37.40.
Mechanical Data
Mounting: Can be mounted on a flat surface with two screws or snapped
Termination: Screw terminals.
Connections: 3 wire wye or delta.
Vibration: Chatterless operation 5 to 60 Hz., 0.030 in.(0.762 mm)
Status Indication: "Contacts Transferred" LED plus four additional LEDs
Weight: 24 oz. (625g) approximately.
Dimensions are shown for
reference purposes only.
Function
Monitoring Specifications
Threshold Accuracy: 0.2% of the average of 10 consecutive measure-
Response Time: Phase loss and phase reversal: 2 line cycles +5 ms.
Output Data
Arrangement: 1 Form A (SPST-NO) + 1 Form B (SPST-NC).
Rating: 8A @ 250VAC, resistive; 3A @ 30VDC, resistive;
Expected Mechcanical Life: 10,000,000 operations.
Expected Electrical Life: 100,000 operations at rated resistive load.
Initial Dielectric Strength
Between Input Terminals and Case or Active Circuitry: 2,200V.
Between Relay Contacts and Active Circuitry: 1,500V.
Environmental Data
Temperature Range: Storage: -40 C to +75 C.
Three phase power quality monitor.
1/4 HP @ 125/250VAC; 275VAC pilot duty.
on/off a furnished adapter plate which has been pre-mounted
on a flat surface. Can also be mounted on a 300-volt machine
tool relay channel using the adapter plate. Direct mounting (no
adapter plate used) on a symmetrical DIN track is also possible.
amplitude, 1 minute sweep.
Undervoltage and phase imbalance: See Figures 1 and 2
on the following page.
to designate the specific fault that released the relay.
PMA
110 to 120VAC; 208 to 240VAC; 380 to 440VAC;
440 to 480VAC; 550 to 600VAC..
264VAC for the 208 to 240VAC model;
484VAC for the 380 to 440VAC model;
528VAC for the 440 to 480VAC model;
650VAC for the 550 to 600VAC model.
ments of the threshold point at any fixed temperature
within the operating temperature range.
ments of the threshold point over the operating
temperature range.
Operating: -10 C to +60 C.
2% of the average of 10 consecutive measure-
Dimensions are in inches over
(millimeters) unless otherwise
specified.
PMB
Catalog 1308242
Issued 3-03
PMA/PMB
Three Phase
Power Quality Monitor
• Monitors deviation from nominal system voltage, phase
• Locking potentiometer prevents tampering (PMA only).
• Start-up delay permits staggered restarting (PMB only).
• Four LEDs show nature of temporary/sustained faults.
• 3-wire wye or delta connections for simple installation.
• Calibrated nominal voltage potentiometer assures
• Superior transient immunity per ANSI C37.40.
• Not fooled by back EMF.
• 8 user-selectable thresholds – 4 undervoltage and 4
• Manual or automatic reset for application flexibility.
• Suitable for commonly used grounded or ungrounded
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that user also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Outline Dimensions
Ordering Information
Authorized distributors are likely to stock the following:
None at present.
3.85
(98)
Quality Monitor
Quality Monitor
Potentiometer
PMA = Power
PMB = Power
with Start-Up
with Locking
imbalance, phase sequence and phase loss.
precise monitoring.
phase imbalance – match protection to load.
three-phase systems.
PMA
Series
Delay
File E60363
File LR29186
Specifications and availability
subject to change.
|
2.18
(55)
CAPTIVE CLAMP SCREW
#8 HEAD #6-32 BODY
LA = 110 to 120VAC, 50/60 Hz.
LB = 208 to 240VAC, 50/60 Hz.
LG = 380 to 440VAC, 50/60 Hz.
LC = 440 to 480VAC, 50/60 Hz.
LD = 550 to 600VAC, 50/60 Hz.
Nominal Operating Voltage
3.35
(85)
Adapter
LB
Plate
|
(114)
4.48
series
(125)
4.94
DIA. TYP.
3.12
(79)
.218
.28
(7)
(6)
(135)
(15)
5.31
.58
S = "Contacts
Status Indicators
Transferred" and
four fault status
indicators
2.18
(55)
S
|
|
|
|
|
|
3.35
(85)
1.09
.32
(27)
(8)
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
1.67
(42)
.22
(6)
L = Low (2-4%)
H = High (5-10%)
Phase Imbalance
3.68
(93)
.37
(9)
AGASTAT
Threshold
(23)
1.78
.89
(45)
L
|
(23)
.89
.36
(9)
.04
(1)
1305

Related parts for 2-1419130-4