TS81102G0VTP E2V, TS81102G0VTP Datasheet - Page 6

no-image

TS81102G0VTP

Manufacturer Part Number
TS81102G0VTP
Description
Manufacturer
E2V
Datasheet

Specifications of TS81102G0VTP

Operating Supply Voltage (typ)
5V
Operating Supply Voltage (max)
5.25V
Operating Temp Range
-40C to 110C
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Lead Free Status / RoHS Status
Not Compliant
Asynchronous
Reset
(ASYNCRESET)
Synchronous
Reset
(SYNCRESET)
6
TS81102G0
Figure 5. Asynchronous Reset
The Asynchronous Reset is a master reset of the port selection, which works on TTL levels. It
is active on the high level. During an asynchronous reset, the clock must be in a known state.
It is used to start the DMUX.
When it is active, it paralyzes the outputs (the output clock and output data remain at the same
level as before the asynchronous reset). When it comes back to its low level, the DMUX starts:
the outputs are active and the first processed data is on port A.
Figure 6. Synchronous Reset
The DMUX can be synchronously reset to a programmable state depending on the conversion
ratio. The clock must not be stopped during reset. The synchronization signal is a clock
(SyncRest) whose frequency is FS/8*n where n is an integer (n = 1,2,3,…) in 1:8 mode and
FS/4*n in 1:4 mode. The front edge of this clock is synchronized with Clkln inside the DMUX,
and generates a 200 ps reset pulse. This reset pulse occurs during a fixed level of Clkln.
If the DMUX was synchronized with Syncreset previous to a possible loss of synchronization,
then the output data is immediately correct, no modification can be seen at the output of the
DMUX, and no data is lost (“Internal Timing Diagram” on page 3).
If the DMUX was not synchronized with SyncReset previous to a possible loss of synchroniza-
tion, then the output data and data ready of the DMUX are changed. The output data is correct
after a number of input clocks corresponding to the pipeline delay (“Timing Diagrams with Syn-
chronous Reset” on page 19).
SyncReset = FS/8
Port G selected
Port C selected
Port D selected
Port H selected
Port A selected
Port B selected
Port E selected
Port F selected
Port C selected
Port D selected
Port G selected
Port H selected
Port A selected
Port B selected
Port E selected
Port F selected
AsyncReset
Internal reset
CLKIN
pulse
DR/2
FS
2105C–BDC–11/03