HFCT5201B Avago Technologies US Inc., HFCT5201B Datasheet - Page 6

HFCT5201B

Manufacturer Part Number
HFCT5201B
Description
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of HFCT5201B

Optical Fiber Type
TX/RX
Data Transfer Rate
155Mbps
Operating Temperature Classification
Commercial
Peak Wavelength
1360nm
Operating Supply Voltage (min)
4.75V
Operating Supply Voltage (typ)
5V
Operating Supply Voltage (max)
5.25V
Output Current
30mA
Operating Temp Range
0C to 70C
Pin Count
18
Lead Free Status / RoHS Status
Not Compliant
Performance Specifications
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause catastrophic damage to the device. Limits apply to each parame‑
ter in isolation, all other parameters having values within the recommended operating conditions. It should not be assumed that
limiting values of more than one parameter can be applied to the product at the same time. Exposure to the absolute maximum
Operating Environment
Transmitter Section
(Ambient Operating Temperature, V
Notes:
1. 2 m/s air flow required.
2. Output power is power coupled into a single mode fiber.
3. Common mode signal 2.5 V nominal.
4. The power supply current varies with temperature. Maximum current is specified at V
5. Minimum sensitivity and saturation levels for a 2
6. The current excludes the output load current.
Receiver Section
(Ambient Operating Temperature, V
6
Parameter
Storage Temperature
Operating Temperature ‑ HFCT‑5201 A/C
Operating Temperature ‑ HFCT‑5201 B/D
Lead Soldering Temperature/Time
Output Current (other outputs)
Input Voltage
Power Supply Voltage
Parameter
Power Supply Voltage ECL Operation
Power Supply Voltage PECL Operation
Ambient Operating Temperature ‑ HFCT‑5201 A/C T
Ambient Operating Temperature ‑ HFCT‑5201 B/D T
Parameter
Output Center Wavelength
Output Spectral Width (RMS)
Average Optical Output Power
Extinction Ratio
Bias Monitor
Rear Facet Monitor
Tx Disable
Power Supply Current
Output Eye
Parameter
Receiver Sensitivity
Maximum Input Power
Alarm ON
Hysterisis
Power Supply Current
Data Outputs
Alarm Output
terminations) and end of life.
Symbol
lce
Dl
P
E
TX
I
Compliant with Bellcore TR‑NWT‑000253 and ITU recommendation G957
Symbol
I
ECL/PECL
ECL/PECL
CC
CC
CC
CC
R
O
DIS
= 4.75 V to 5.25 V)
= 4.75 V to 5.25 V)
23
‑1 PRBS with 72 ones and 72 zeros inserted. (ITU recommendation G.958).
Minimum
1261
‑15
8.2
V
Minimum
‑31
‑7
‑45
0.5
CC
Symbol
T
I
Symbol
V
V
OUT
S
OP
OP
CC
CC
‑3.2
Typical
0.1
V
140
Typical
Minimum
‑40
‑40
0
0
GND
0
Minimum
‑4.95
+4.75
‑40
0
EE
+1.2
CC
= Maximum@ maximum temperature (not including
Maximum
1360
7.7
‑8
V
Maximum
‑31
4.0
100
Maximum
+85
+85
+70
+260/10
30
V
+6
Maximum
‑5.45
+5.25
+85
+70
CC
CC
Units
nm
dBm
dB
mA/mV 3
V
V
mA
Units
dBm
dBm
dBm
dB
mA
Units
°C
°C
°C
°C/s
mA
V
V
Units
V
V
°C
°C
Notes
2
4
Notes
5
6
Notes
1
1
Notes
1
1

Related parts for HFCT5201B