PAXI0000 Red Lion Controls, PAXI0000 Datasheet - Page 5

1/8 DIN DIGITAL INPUT PANEL METE

PAXI0000

Manufacturer Part Number
PAXI0000
Description
1/8 DIN DIGITAL INPUT PANEL METE
Manufacturer
Red Lion Controls
Series
PAXr
Type
Multimeterr
Datasheets

Specifications of PAXI0000

Display Style
Red Characters, Black Background
Display Type
LED
Display Face Size
3.80" L x 1.95" W (96.5 x 49.5mm)
Display Digits
6
Display Digits - Height
0.560" (14.22mm)
Mounting Type
Panel Mount
Termination
Terminal Block
Voltage - Supply
85 ~ 250VAC
No. Of Digits / Alpha
6
Signal Input Type
Pulse
Character Size
0.56"
Ip/nema Rating
IP65 / NEMA 4X
Panel Cutout Height
1.77"
Display Font Color
Red
Panel Cutout Width
3.62"
Accuracy
±0.01% %
Connection Type
Cage-Clamp
Cut Out, Panel
1/8 DIN
Digit Height
0.56
Dimensions
4.2"L×3.8"W×1.95"H
Display Digit Height
0.56 "
Function
Counter/Rate Indicator
Indicator Type
Counter/Rate Indicator
Number Of Digits
5
Primary Type
Electronic
Range, Measurement
±99999999
Special Features
Programmable Function Keys
Temperature, Operating, Range
0 to 50 °C
Voltage, Supply
85 to 250 VAC
Counter Supply Voltage
85-250VAC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Backlight
-
Measuring Range
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
Q4600348
PAXI SPECIFICATIONS
MAXIMUM SIGNAL FREQUENCIES TABLE
questions with a yes (Y) or no (N). Next determine the Count Mode to be used
for the counter(s). If dual counters are used with different Count Modes, then
the lowest frequency applies to both counters.
Notes:
1. Counter Modes are explained in the Module 1 programming section.
2. If using Rate with single counter with direction or quadrature, assign it to Input A for the listed frequency.
3. * Double the listed value for Rate frequency.
4. Listed values are with frequency DIP switch set on HI frequency.
5. Derate listed frequencies by 20% during serial communications. (Placing a 5 msec. delay between serial characters will eliminate the derating.)
ANNUNCIATORS:
RATE DISPLAY:
COUNTER DISPLAYS:
FUNCTION QUESTIONS
Are any setpoints used?
Is Prescaler Output used?
Is Counter C used?
COUNT MODE
Count x1
Count x2
Quadrature x1
Quadrature x2
Quadrature x4
Rate Only
M
To determine the maximum frequency for the input(s), first answer the
A - Counter A
B - Counter B
C - Counter C
SP1 - setpoint 1 output state
SP2 - setpoint 2 output state
SP3 - setpoint 3 output state
SP4 - setpoint 4 output state
Accuracy: ±0.01%
Minimum Frequency: 0.01 Hz
Maximum Frequency: see Max Signal Frequencies Table.
Maximum Display: 5 Digits: 99999
Adjustable Display (low) Update: 0.1 to 99.9 seconds
Over Range Display: “
Maximum display: 8 digits: ± 99999999 (greater than 6 digits display
Alternates between high order and low order.)
- Rate
- Maximum (High) Rate
- Minimum (Low) Rate
- Upper significant digit display of counter
ODEL
PAXI - 1/8 DIN C
Single: Counter A or B (with/without rate) or Rate only
34
17
22
17
34
N
N
N
8
(Values are in KHz)
N/A
25
13
19
13
N
N
Y
6
21
16
20
16
21
N
N
Y
8
N/A
17
12
17
12
N
Y
Y
6
18
12
34
N
N
Y
9
9
4
(Values are in KHz)
N/A
15
10
Y
N
Y
7
7
3
13
21
11
Y
Y
N
8
8
4
5
N/A
10
11
INPUTS A and B:
PRESCALER OUTPUT:
Y
Y
Y
7
6
3
LOGIC: Input trigger levels V
MAGNETIC PICKUP:
DUAL COUNT MODES:
NPN Open Collector: I
COUNT, RATE AND SLAVE DISPLAY
6-DIGIT 0.56" RED SUNLIGHT READABLE DISPLAY
VARIABLE INTENSITY DISPLAY
10 POINT SCALING (FOR NON-LINEAR PROCESSES)
FOUR SETPOINT ALARM OUTPUTS (W/OPTION CARD)
RETRANSMITTED ANALOG OUTPUT (W/OPTION CARD)
COMMUNICATION AND BUS CAPABILITIES (W/OPTION CARD)
BUS CAPABILITIES; DEVICENET, MODBUS, AND PROFIBUS-DP
CRIMSON PROGRAMMING SOFTWARE
OUNTER
Current sinking: Internal 7.8 KΩ pull-up to +12 VDC, I
Current sourcing: Internal 3.9 KΩ pull-down, 7.3 mA max. @ 28 VDC,
Filter: Damping capacitor provided for switch contact bounce. Limits
Sensitivity: 200 mV peak
Hysteresis: 100 mV
Input impedance: 3.9 KΩ @ 60 Hz
Maximum input voltage: ±40 V peak, 30 Vrms
VDC max. With duty cycle of 25% min. and 50 % max.
Dual: Counter A & B or Rate not assigned to active single counter
9 *
7 *
7 *
DIP switch selectable to accept pulses from a variety of sources
including switch contacts, TTL outputs, magnetic pickups and all
standard RLC sensors.
V
input frequency to 50 Hz and input pulse widths to 10 msec. minimum.
When any dual count mode is used, then User Inputs 1 and/or 2 will
accept the second signal of each signal pair. The user inputs do not have
the Logic/Mag, HI/LO Freq, and Sink/Source input setup switches. The
user inputs are inherently a logic input with no low frequency filtering.
Any mechanical contacts used for these inputs in a dual count mode
must be debounced externally. The user input may only be selected for
sink/source by the User Jumper placement.
13
N
N
N
MAX
(Values are in KHz)
= 30 VDC.
7 *
6 *
6 *
12
N
N
Y
SNK
9 *
6 *
6 *
13
N
Y
N
/R
= 100 mA max. @ V
IL
7 *
5 *
5 *
= 1.5 V max.; V
11
N
Y
Y
ATE
5 *
4 *
4 *
Y
N
N
9
(Values are in KHz)
M
OL
IH
3.5 *
3.5 *
7.5
= 1 VDC max. V
4 *
= 3.75 V min.
Y
N
Y
ETER
MAX
3.5 *
3.5 *
5 *
Y
Y
N
9
= 1.9 mA.
OH
4 *
3 *
3 *
Y
Y
Y
7
= 30