AD7738BRU Analog Devices Inc, AD7738BRU Datasheet - Page 15

no-image

AD7738BRU

Manufacturer Part Number
AD7738BRU
Description
IC ADC 24BIT 8-CH 28-TSSOP
Manufacturer
Analog Devices Inc
Datasheet

Specifications of AD7738BRU

Rohs Status
RoHS non-compliant
Number Of Bits
24
Sampling Rate (per Second)
15.4k
Data Interface
DSP, MICROWIRE™, QSPI™, Serial, SPI™
Number Of Converters
1
Power Dissipation (max)
100mW
Voltage Supply Source
Analog and Digital
Operating Temperature
-40°C ~ 105°C
Mounting Type
Surface Mount
Package / Case
28-TSSOP (0.173", 4.40mm Width)
For Use With
EVAL-AD7738EBZ - BOARD EVAL FOR AD7738

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD7738BRU
Quantity:
10
Part Number:
AD7738BRUZ
Manufacturer:
ADI
Quantity:
1 000
Part Number:
AD7738BRUZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD7738BRUZ-REEL7
Manufacturer:
ADI
Quantity:
1 000
AD7738
Checksum Register
16 Bits, Read/Write Register, Address 05h
This register is described in the “AD7732/34/38 Checksum Register” Technical Note.
ADC Zero Scale Calibration Register
24 Bits, Read/Write Register, Address 06h, Default Value 800000h
The register holds the ADC Zero-Scale Calibration coefficient. The value in this register is used in conjunction with the value in the
ADC Full-Scale Calibration register and corresponding Channel Zero-Scale and Channel Full-Scale Calibration registers to scale
digitally all channels’ conversion results. The value in this register is updated automatically following the execution of an ADC Zero-
Scale ADC Self-Calibration. Writing to this register is possible in the Idle Mode only. See the calibration description for more details.
ADC Full-Scale Register
24 Bits, Read/Write Register, Address 07h, Default Value 800000h
The register holds the ADC Full-Scale coefficient. The user is advised not to change the default configuration of this register.
Channel Data Registers
16/24 Bits, Read-Only Registers, Address 08h–0Fh, Default Width 16 Bits, Default Value 8000h
These registers contain the most up-to-date conversion results corresponding to each analog input channel. The 16- or 24-bit data
width can be configured by setting the “16/24” bit in the Mode register. The relevant RDY bit in the Channel Status register goes
high when the result is updated. The RDY bit will return low once the Data register reading has begun. The RDY pin can be configured
to indicate when any channel has unread data or waits until all enabled channels have unread data. If any Channel Data Register read
operation is in progress when the new result is updated, then no update of the Data register occurs. This is to avoid getting corrupted
data. Reading the Status registers can be associated with reading the Data registers in the Dump mode. Reading the Status registers is
always associated with reading the Data registers in the Continuous Read mode. See the digital interface description for more details.
Channel Zero-Scale Calibration Registers
24 Bits, Read/Write Registers, Address 10h–17h, Default Value 800000h
These registers hold the particular channel Zero-Scale Calibration coefficients. The value in these registers is used in conjunction
with the value in the corresponding Channel Full-Scale Calibration register, the ADC Zero-Scale Calibration register, and ADC
Full-Scale Calibration register to scale digitally the particular channel conversion results. The value in this register is updated auto-
matically following the execution of a Channel Zero-Scale System Calibration.
The format of the Channel Zero-Scale Calibration register is a sign bit and 22 bits unsigned value.
Writing this register is possible in the Idle Mode only. See the calibration description for more details.
Channel Full-Scale Calibration Registers
24 Bits, Read/Write Registers, Address 18h–1Fh, Default Value 200000h
These registers hold the particular channel Full-Scale Calibration coefficients. The value in these registers is used in conjunction with
the value in the corresponding Channel Zero-Scale Calibration register, the ADC Zero-Scale Calibration register, and ADC Full
Scale Calibration register to scale digitally the particular channel conversion results. The value in this register is updated automati-
cally following the execution of a Channel Full-Scale System Calibration. Writing this register is possible in the Idle mode only. See
the calibration description for more details.
REV. 0
–15–

Related parts for AD7738BRU