F3SJ-A0595P30 Omron, F3SJ-A0595P30 Datasheet - Page 25

no-image

F3SJ-A0595P30

Manufacturer Part Number
F3SJ-A0595P30
Description
F3SJ-A Safety Light Curtain, 30mm Resolution, 595 Mm Protected Height
Manufacturer
Omron
Datasheet
Basic Connection for Muting System
For PNP output (See page 26 for NPN output wiring.)
Wiring when using muting and external device monitoring functions
Wiring when the external device monitoring function will not be used
• Use a setting tool to set the external device monitoring function to "Disabled."
• When using an auxiliary output 1 that has not been changed (output operation mode is "control output data," and inverse of control output signals
is "Enabled), the external device monitoring function will be disabled when auxiliary output 1 and the external device monitoring input are
connected as shown below.
(Gray) Communication line (+)
(Pink) Communication line (−)
*1. Use a switch for small loads (input specifications: 24 V, 1.8 mA)
*2. When using the interlock function, this also functions as an interlock reset switch. (Must be set with a setting tool.)
*3. The F3SJ will operate even if K3 is not connected.
*4. Connect the muting lamp to either the external indicator output or auxiliary output 1 for the emitter or the receiver. When
*5. Two-wire sensors cannot be used.
S1:
S2:
A1:
B1:
K1, K2: Relay or other device that controls hazardous parts of the machine
K3:
M1:
connecting the muting lamp to auxiliary output 1, the parameter must be changed with a setting tool.
*5 *5
B1
External test switch (connect to 0 V if the switch is not necessary.)
Lockout reset switch (connect to 24 V if the switch is not necessary.)
Contact by muting sensor A1
Contact by muting sensor B1
Load or PLC, etc. (for monitoring)
Muting lamp
A1 S1
*1 *1
*4
S2
M1
*2
Communication line (+)
Communica-
tion line (−)
(Pink)
(Gray)
*
K3
K1
*4
K2
K1
K2
K3
*3
*4
K1
K2
K1, K2: Relay or other device that controls
K3:
* The F3SJ operates even when K3 is not
connected.
When K3 is not necessary, connect auxiliary output
1 only to the external device monitoring input.
0 V
24 VDC
hazardous parts of the machine
Load, PLC, etc. (for monitoring)
Power
supply
0 V
24 VDC
Power
supply
F3SJ Ver.2