F3SJ-A Safety Light Curtain, 30mm Resolution, 595 Mm Protected Height
Manufacturer
Omron
Datasheet
Indicator and I/O Settings
Auxiliary Output (Non-safety) and External Indicator Output (Non-safety)
Summary
A setting tool can be used to change the allocation of auxiliary outputs
1 and 2, and external indicator outputs 1 and 2.
Do not use the auxiliary outputs or external indicator outputs for safety
purposes. Serious injury may result if an output fails and a person is
not detected.
Example Applications
An auxiliary output or external indicator output can be connected to
an incandescent light to function as a broken-wire or short-circuit
detector. Refer to the User's Manual for details.
Output Operation Modes (when allocated to an auxiliary output or external indicator output)
Note: When "specified light beam output" is allocated as the output operation mode for auxiliary output 1 or 2 or external indicator output 1 or 2,
*1. A light blockage was detected even though the output is not turned OFF because the blockage occurred at a light beam subject to fixed
*2. The fixed blanking light beams or floating blanking light beams must be set.
*3. The specified light beam must be set.
*4. The warning zone light beams must be set.
• Allocating a lockout output or warning zone output to an auxiliary
• Connecting an external indicator to an auxiliary output and making
Control output
Light intensity diagnosis *1
Error/Lockout
Muting/Override
Blanking/Warning Zone *2
Specified light beam output *3
Power ON time
Warning zone *4
Test input ON
Blanking light beam incident light
Interlock
Muting error
Number of load switching operations
exceeded
Information trigger
Individual linked sensor output (channel
1)
Individual linked sensor output (channel
2)
Individual linked sensor output (channel
3)
Individual linked sensor output (channel
4)
output
it flash
blanking, floating blanking, or muting. Blockages are also not processed during overrides.
that mode cannot be allocated to the other output operations.
Output operation mode
!WARNING
(Output will go ON in the following situation.)
The control output is ON
The F3SJ is ON and the received light intensity
is 100% to 130% of the threshold value for more
than 10 seconds.
The F3SJ is in error or lockout status.
The F3SJ is in muting or override status.
The fixed blanking, floating blanking, or warning
zone function is enabled.
A specified light beam is blocked.
The power ON time has exceeded the threshold
value.
Light is blocked in the warning zone.
The test input went ON.
A fixed or floating light beam is receiving
incident light.
The F3SJ is in interlock status.
The F3SJ is in muting error status.
The number of load switching operations
exceeded the threshold value.
An interlock, lockout, or muting error has
occurred.
Channel 1 control output is ON when Units are
linked in series.
Channel 2 control output is ON when Units are
linked in series.
Channel 3 control output is ON when Units are
linked in series.
Channel 4 control output is ON when Units are
linked in series.
Description of operation
×
×
❍ (Auxiliary output 1 only) ❍ (Auxiliary output 1 only)
❍ (Auxiliary output 1 only) ❍ (Auxiliary output 1 only)
❍ (Auxiliary output 1 only) ❍ (Auxiliary output 1 only)
❍ (Auxiliary output 1 only) ❍ (Auxiliary output 1 only)
Setting Console
SD Manager Setting
Support Software
F3SJ Ver.2