F3SJ-A0595P30 Omron, F3SJ-A0595P30 Datasheet - Page 60

no-image

F3SJ-A0595P30

Manufacturer Part Number
F3SJ-A0595P30
Description
F3SJ-A Safety Light Curtain, 30mm Resolution, 595 Mm Protected Height
Manufacturer
Omron
Datasheet
Example of a Safety Circuit with the Muting System
For PNP output
Wiring for muting function with single F3SJ application (category 4)
When two muting sensors are connected
* The output operation mode for auxiliary output 1 is control output data/inverse of control output signals enabled (default setting).
Note: Start interlock and restart interlock can be used with a setting tool.
• Attaching a keycap for muting (F39-CN6) enables the muting function to be used.
Timing Chart
KM1, KM2 N.O. contact
KM1, KM2 N.C. contact
F39-JC@A-L
Light interrupted
Muting input 1
Muting input 2
Control output
Muting sensor
Light incident
Emitter
(PNP output)
PLC input *
PLC output
Reflector
Muting lamp
(external indicator)
Communication line (+)
E1
Communica-
+24 VDC
tion line (−)
(Gray)
(Pink)
0 V
F39-JC@A-D
KM1
KM2
S1:
S2:
KM1, KM2: Safety relay with forcibly-guided contacts (G7SA) or
KM3:
M:
E1:
PLC:
Muting sensor: Retro-reflective photoelectric sensor (E3Z-R81)
PLC
IN
Receiver
KM1
External test switch (connect to 0 V if the switch is not
necessary.)
Lockout reset switch (connect to 24 V if the switch is not
necessary.)
magnetic contactor
Solid state contactor (G3J)
3-phase motor
24 VDC power supply (S82K)
Programmable controller (Used for monitoring -- not
related to safety system)
KM2
OUT
• Auto reset mode
• Using external device monitoring
function
M
F3SJ Ver.2
KM1
KM2
KM3
60