Specifications of EP2C50F672I8N

Number Of Logic Elements/cells
50528
Number Of Labs/clbs
3158
Total Ram Bits
594432
Number Of I /o
450
Voltage - Supply
1.15 V ~ 1.25 V
Mounting Type
Surface Mount
Operating Temperature
-40°C ~ 100°C
Package / Case
672-FBGA
Family Name
Cyclone® II
Number Of Logic Blocks/elements
50528
# I/os (max)
450
Frequency (max)
402.58MHz
Process Technology
90nm
Operating Supply Voltage (typ)
1.2V
Logic Cells
50528
Ram Bits
594432
Operating Supply Voltage (min)
1.15V
Operating Supply Voltage (max)
1.25V
Operating Temp Range
-40C to 100C
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
672
Package Type
FBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-
Lead Free Status / Rohs Status
Compliant
Other names
544-2127

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP2C50F672I8N
Manufacturer:
ALTERA
Quantity:
1 045
Part Number:
EP2C50F672I8N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP2C50F672I8N
Manufacturer:
ALTERA
Quantity:
40
Part Number:
EP2C50F672I8N
Manufacturer:
ALTERA
0
Part Number:
EP2C50F672I8N
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
EP2C50F672I8N
0
Altera Corporation
February 2008
Notes to
(1)
(2)
(3)
TM4KCLR
t
t
t
C I N
C O U T
P L L C I N
Table 5–19. M4K Block Internal Timing Microparameters (Part 3 of 3)
Table 5–21. EP2C5/A Column Pins Global Clock Timing Parameters (Part 1 of 2)
Parameter
For the –6 speed grades, the minimum timing is for the commercial temperature grade. The –7 speed grade devices
offer the automotive temperature grade. The –8 speed grade devices offer the industrial temperature grade.
For each parameter of the –7 speed grade columns, the value in the first row represents the minimum timing
parameter for automotive devices. The second row represents the minimum timing parameter for commercial
devices.
For each parameter of the –8 speed grade columns, the value in the first row represents the minimum timing
parameter for industrial devices. The second row represents the minimum timing parameter for commercial
devices.
Table
Parameter
5–19:
Automotive
Industrial/
–0.188
1.283
1.297
Fast Corner
Cyclone II Clock Timing Parameters
Refer to
EP2C5/A Clock Timing Parameters
Tables 5–21
devices.
t
t
t
t
C I N
C O U T
P L L C I N
P L L C O U T
Table 5–20. Cyclone II Clock Timing Parameters
Commercial
Symbol
–0.201
–6 Speed Grade
1.343
1.358
Min
191
Tables 5–20
and
–6 Speed
Delay from clock pad to I/O input register
Delay from clock pad to I/O output register
Delay from PLL
Delay from PLL
5–22
Max
Grade
2.329
2.363
0.076
(1)
through
show the clock timing parameters for EP2C5/A
–7 Speed Grade
Min
244
217
5–34
–7 Speed
DC Characteristics and Timing Specifications
Grade
2.484
2.516
0.038
inclk
inclk
(1)
for Cyclone II clock timing parameters.
Cyclone II Device Handbook, Volume 1
pad to I/O input register
pad to I/O output register
Max
Parameter
(2)
–7 Speed
Grade
2.688
2.717
0.042
(2)
–8 Speed Grade
Min
244
244
–8 Speed
Grade
2.688
2.717
0.052
Max
(3)
Unit
ns
ns
ns
Unit
5–23
ps
ps